EXCEPTION: Transfer surfaces for imaging equipment with bores shall be permitted to be 21 inches (535 mm) wide minimum but shall not be permitted to be less than the full width of the examination...
Search Results "Fixed Equipment"
-
M301.2.3.1 End Transfer Surface
-
M301.2.3.2 Side Transfer Surface
EXCEPTION: Transfer surfaces for imaging equipment with bores shall be permitted to be 21 inches (535 mm) wide minimum but shall not be permitted to be less than the full width of the examination...
-
M301.1 General (Section-by-Section Analysis)
The MDE NPRM proposed that all diagnostic equipment used by patients in a supine, prone, or side-lying position must comply with the technical requirements of proposed section M301....
-
Section 37.121 Requirement for Comparable Complementary Paratransit Service
Section 37.121 Requirement for Comparable Complementary Paratransit Service This section sets forth the basic requirement that all public entities who operate a fixed route system have...
-
11B-226.1 General
Because they are furnishings, dining tables that are not fixed to the building or structure are not covered by the CBC, however, dining tables provided at a place of public accommodation...
-
Clear Width: ADA Standard Section 405.5
Section 405.5 covers the current ADA Standards for the clear width requirements of ramps.
-
11B-221.2.4 Temporary structures
Exception: When an entire seating section is placed on temporary platforms or other movable structures in an area where fixed seating is not provided, in order to increase seating for an...
-
Hologic, Inc.
Equivalent care can be provided with biopsy accessories attached to upright mammography equipment with patients in seated or decubitus positions....
-
M102.1 Defined Terms (Section-by-Section Analysis)
The MDE NPRM proposed definitions for enforcing authority, medical diagnostic equipment, operable parts, and transfer surface....
-
3.3 Equipment Barriers and Solutions
Barriers Solutions Simple/Low cost Involved / High cost Display and/or controls on the equipment is not accessible Put tactile labels...
-
5.6.1 Stirrups for Equipment Used by Patient in Supine, Prone, or Side-Lying Position
5.6.1 Stirrups for Equipment Used by Patient in Supine, Prone, or Side-Lying Position....
-
Accessible Medical Equipment
We provide participants transfer assistance on and off of equipment (this includes use of lift equipment when needed). ...
-
5.8.1.1 Clear Platform Size Recommendation
5.8.1.1 Clear Platform Size Recommendation The Committee recommends a platform size with a minimum clear width of 32 inches and a minimum clear length of 40 inches. Rationale...
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches.
-
221.8 Temporary Platforms or Other Movable Structures
obstructed by) temporary platforms or other movable structures, except that when an entire seating section is placed on temporary platforms or other movable structures in an area where fixed...
-
F206.2.4 Spaces and Elements
In assembly areas with fixed seating required to comply with F221, an accessible route shall not be required to serve fixed seating where wheelchair spaces required to be on an accessible...
-
206.2.4 Spaces and Elements
In assembly areas with fixed seating required to comply with 221, an accessible route shall not be required to serve fixed seating where wheelchair spaces required to be on an accessible...
- Aqua Creek Scout Pool and Spa Lift Informational Video
- S.R. Smith PAL Pool Lift Video 4: Resolution
- S.R. Smith PAL Pool Lift Video 1: Installation and Operation
- S.R. Smith PAL Pool Lift Video 3: Advanced Troubleshooting
- S.R. Smith PAL Pool Lift Video 2: Basic Troubleshooting
-
15. Caring for Service Animals
A paratransit or fixed route passenger's request that the driver take charge of a service animal may be denied....
-
M302.2.4 Transfer Sides (Section-by-Section Analysis)
In the MDE NPRM, the transfer side provision for diagnostic equipment used by patients in the seated position required transfer surfaces to have the option to transfer from a mobility device...