Door Swing [§304.4] and Other Space Requirements Doors can swing into the turning space....
Search Results "Clear Ground Space"
Commonly Searched Documents
-
Door Swing [§304.4] and Other Space Requirements
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADA Standards] 608.2.2.1...
-
Turning Space: ADA Standard Section 612.3
Section 612.3 covers the current ADA Standards for turning space within saunas and steam rooms.
- Neo-Metro Urinal Divider Number 8949-N
-
902.2 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for a forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided....
-
902.2 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for a forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided....
-
CLEAR
[DSA-AC] Unobstructed.
-
808.3 Clear Floor Space
808.3 Clear Floor Space. Each jury box and witness stand shall have, within its defined area, clear floor space complying with 305....
-
4.24.5 Clear Floor Space
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a sink to allow forward approach....
-
4.24.5 CLEAR FLOOR SPACE
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a sink to allow forward approach....
-
Is clear floor space required to be centered on elements?
The standards require the clear floor space to be centered on wheelchair accessible drinking fountains (forward approach), kitchen work surfaces, (forward approach), and washers and dryers...
-
4.16.2 Clear Floor Space
4.16.2 Clear Floor Space. In order to accommodate independent wheelchair use, guidelines for clear floor space in ADAAG vary according to path of approach to the toilet....
-
902.4.1 Clear Floor or Ground Space
902.4.1 Clear Floor or Ground Space. A clear floor space complying with 305 positioned for forward approach shall be provided....
-
403.5.3 Passing Spaces
403.5.3 Passing Spaces. An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
-
403.5.3 Passing Spaces
An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
-
802.1.1 Floor or Ground Surface
802.1.1 Floor or Ground Surface. The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted....
-
403.5.3 Passing Spaces
An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
-
Slope: ADA Standard Section 1002.4.2
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
11B-1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
304.2 Floor or Ground Surfaces
304.2 Floor or Ground Surfaces. Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permitted....
-
A4.2.1(3) Space Requirements for Passing
(3) Space Requirements for Passing....
-
A4.2.1(3) Space Requirements for Passing
(3) Space Requirements for Passing....
-
304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
808.3 Clear Floor Space
Each jury box and witness stand shall have, within its defined area, clear floor space complying with 305....