The clear floor space shall be positioned for parallel approach to the side of the bed....
Search Results "Approach"
-
11B-807.2.3 Beds
-
§ 38.127(a)
(a) Sleeping compartments required to be accessible shall be designed so as to allow a person using a wheelchair or mobility aid to enter, maneuver within and approach and use each element...
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
11B-807.2.3 Beds
The clear floor space shall be positioned for parallel approach to the side of the bed....
-
11B-807.2.3 Beds
The clear floor space shall be positioned for parallel approach to the side of the bed....
-
807.2.3 Beds
The clear floor space shall be positioned for parallel approach to the side of the bed....
-
INFORMATION REQUIREMENTS OF PEDESTRIANS WITH VISION DISABILITIES
In the absence of traffic signals, the pedestrian would need to either detect that no vehicles are approaching, or that vehicles are yielding in all lanes....
-
1133A.2, Item 3
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by Section 1133A...
-
1133A.2.1, Item 1
U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm)....
-
8.4 Card Catalogs and Magazine Displays
Maximum reach height shall comply with 4.2, with a height of 48 in (1220 mm) preferred irrespective of approach allowed....
-
1133A.2.1, Item 1
U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm)....
-
1133A.2, Item 3
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by Section 1133A...
-
Elevated Play Component
A play component that is approached above or below grade and that is part of a composite play structure consisting of two or more play components attached or functionally linked to create...
-
I. Parking Garage
Does the parking garage serving the lodging facility allow at least 98" of vertical clearance for vehicles with raised roofs to approach, use and exit the accessible parking spaces?...
-
4.17.5* DOORS
If toilet stall approach is from the latch side of the stall door, clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in (1065 mm)....
-
409.3 Elevator Doors
EXCEPTION: Doors shall not be required to comply with the maneuvering clearance requirements in 404.2.4.1 for approaches to the push side of swinging doors....
-
106.5.27 Elevated Play Component
A play component that is approached above or below grade and that is part of a composite play structure consisting of two or more play components attached or functionally linked to create...
-
1133A.2, Item 4
The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work space, appliance...
-
K4
drink, condiment, and tableware dispensers are provided, are dispensers and operating controls mounted no higher than 54 inches above the floor if clear floor space is provided for a side approach...
-
1c
Is there a 36" wide by 48" long clear floor space directly outside the shower for persons who use wheelchairs to approach and use the shower as shown in Figure 35(a) above?...
-
I1a
For a side approach (clear floor space at least 30 inches long x 48 inches wide), is the coin slot no higher than 54 inches above the floor?...
-
180 Turns Around Obstructions
The clear width must be at least 48” at the turn and 42” minimum approaching the turn (unless the clear width at the turn is 60” minimum)....
-
Maintaining Concentration
office space to minimize visual distractions Relocate employee’s office space away from visual distractions To reduce tactile distractions: Instruct other employees to approach...
-
11B-607.2 Clearance
Clearance in front of bathtubs shall extend the length of the bathtub and shall be 48 inches (1219 mm) wide minimum for forward approach and 30 inches (762 mm) wide minimum for parallel...