Angled (Front-In) Parking
ADAAG's requirement for an access aisle on either side of a space (they can be shared by two spaces) is based on the assumption that drivers can head in or back in as needed....
-
F202.3 Alterations
The final rule adds Exception 4 to this section, which applies to altered elements and spaces....
-
Section 4.1.2, Accessible Sites and Exterior Facilities: New Construction (Section-By-Section Analysis and Response to Comments)
Interior elements and spaces are covered by Sec.4.1.3....
-
Problem Four
Problem Four: No sign with the international symbol of accessibility is installed at each accessible parking space....
-
11B-703.5.5 Character height
Exception: Where provided, floor plans providing emergency procedures information in accordance with Title 19 shall not be required to comply with Section 11B-703.5.5....
-
11B-608.6 Shower spray unit and water
One shower head shall be located at a height of 48 inches (1219 mm) maximum above the shower finish floor....
-
Parking
Parking The chart below indicates the number of accessible spaces required by the 2010 Standards. One out of every six accessible spaces must be van-accessible....
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions....
-
407.4.6.2 Buttons
Car control buttons with floor designations shall comply with 407.4.6.2 and shall be raised or flush. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground....
-
409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (13 mm) under rated loading to zero loading conditions....
-
2. Rear grab bar
Rear grab bar: There is a grab bar behind the toilet that is at least 36 inches long and from 33 to 36 inches above the floor....
-
407.4.6.2 Buttons
Car control buttons with floor designations shall comply with 407.4.6.2 and shall be raised or flush. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground....
-
904.5.2 Tray Slides
The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
6. Toilet Seat
Is the toilet seat in each accessible toilet room between 17"-19" above the floor? [ADA Stds. 4.16.3] Yes __ No __ N/A __ Comments: _____________________________________...
-
H28
Is the surface of the toilet seat in this 36-inch-wide stall 17 to 19 inches above the floor? [ADA Standards §§ 4.16.3; 4.22.4] Yes No...
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground....
-
11B-904.5.2 Tray slides
The tops of tray slides shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground....
-
6e.
Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach? Yes _____ No _____...
-
4.19.6* Mirrors
Mirrors shall be mounted with the bottom edge of the reflecting surface no higher than 40 in (1015 mm) above the finish floor (see Fig. 31)....