First is the requirement to survey existing paratransit services within the service area. This is required by section 223(c)(8) of the ADA....
Search Results "Raised Work Area"
-
Section 37.137 Paratransit Plan Development
-
Definition of "wheelchair." (Section-by-Section Analysis)
, July 26, 1990, 104 Stat. 372, 42 U.S.C. 12207, renumbered section 508(c)(2), Public Law 110–325 section 6(a)(2), Sept. 25, 2008, 122 Stat. 3558), which pertains to Federal wilderness areas...
-
I. Ensuring Compliance Now and In the Future
locations with pedestrian crossings providing access to local government facilities, bus stops and other transportation services, public accommodations, business districts, and residential areas...
-
Introduction
The four issues identified for white papers were in the areas of: Effective Communication: What Visitors with Vision Loss Want Museums and Parks to Know about Effective Communication...
- Gamco Horizontal Wall-Mounted Baby Changing Station Cream - BCS-1
- Gamco Horizontal Wall-Mounted Baby Changing Station Grey - BCS-2
-
§382.157(c)
Data concerning a passenger's disability must be recorded separately in the following areas: vision impaired, hearing impaired, vision and hearing impaired, mentally impaired, communicable...
-
Swimming Pools
Pool walls at diving areas and in areas where swimmers cannot enter because of landscaping or adjacent structures are still counted as part of the pool’s total linear feet....
-
Accessible Routes
must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level, doors, egress, and areas...
-
C. Accessibility Within Toilet Rooms
Is there an area within the toilet room where a person who uses a wheelchair or mobility device can turn around - either a minimum 60-inch diameter circle or a “T”-shaped turn area?...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
A. Finish and Contrast
Contrast in percent shall be determined by: Contrast=[B−B)/B] × 100 Where B = light reflectance value (LRV) of the lighter area and B = light reflectance value (LRV) of the darker...
-
11B-705.1.1.3.2
Contrast in percent shall be determined by: Contrast percent = [(B1-B2)/B1] x 100 percent where B1 = light reflectance value (LRV) of the lighter area and B2 = light reflectance...
-
11B-705.1.1.3.2
Contrast in percent shall be determined by: Contrast percent = [(B1-B2)/B1] x 100 percent where B1 = light reflectance value (LRV) of the lighter area and B2 = light reflectance...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
- National Consortium on Leadership and Disability for Youth (NCLD/Y)
-
§ 36.406(f)(4)(ii)
(ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing...
-
1002 Amusement Rides
This section also addresses access at loading and unloading areas and provides criteria for wheelchair spaces, ride seats designed for transfer, and transfer devices....
-
505.3 Continuity
EXCEPTION: In assembly areas, handrails on ramps shall not be required to be continuous in aisles serving seating....
-
Maps/floor plans
at the front desk for use during the Museum visit an up-to-date tactile map of the Museum's current floor plan, including temporary exhibitions, changes to the permanent exhibition and areas...
-
Common Technical Requirements
For instance, if five benches are provided at a viewing area, at least 20 percent (or one) of the benches must comply with the technical requirements for benches....
-
§ 36.406(f)(4)(ii)
(ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing...
-
11B-608.6 Shower spray unit and water
Corrects prior drafting error by limiting the types of facilities that are allowed to use the vandalism prone area exception and requiring one of the two shower heads to be a maximum of...
-
§ 35.151(g)(4)(ii)
(ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing...