At least one toilet facility or bathing facility for each sex on each floor that has toilet facilities or bathing facilities shall comply with F213.2 and F213.3....
Search Results "Comply With"
-
F202.6.3.1 Multiple Facilities
-
11B-809.5.6 Site, building, or floor entrance
Where a system, including a closed-circuit system, permitting voice communication between a visitor and the occupant of the residential dwelling unit is provided, the system shall comply...
-
1008.4.1 Turning Space
At least one turning space complying with 304 shall be provided on the same level as play components....
-
1002.6.3 Wheelchair Storage Space
Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress or accessible...
-
1008.2.6.2 Use Zones
Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
1008.3.2 Transfer Steps
Transfer steps shall comply with 1008.3.2....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
223.3 Long-Term Care Facilities
In licensed long-term care facilities, at least 50 percent, but no fewer than one, of each type of resident sleeping room shall provide mobility features complying with 805....
-
233.3.1.2 Residential Dwelling Units with Communication Features
In facilities with residential dwelling units, at least 2 percent, but no fewer than one unit, of the total number of residential dwelling units shall provide communication features complying...
-
234.4.2 Minimum Number
characteristics of an amusement ride are altered to the extent that the amusement ride's performance differs from that specified by the manufacturer or the original design, the amusement ride shall comply...
-
1008.4.1 Turning Space
At least one turning space complying with 304 shall be provided on the same level as play components....
-
§27.121(a) Cooperation and assistance.
Departmental official, to the fullest extent practicable, seeks the cooperation of recipients in securing compliance with this part and provides assistance and guidance to recipients to help them comply...
-
T403.1 General
Lifts shall comply with T403 and the National Highway Traffic Safety Administration’s Federal Motor Vehicle Safety Standards (FMVSS) for public use lifts at 49 CFR 571.403 and 571.404....
-
T215.2.4 Destination and Route Signs
The signs shall be illuminated and comply with T702....
-
§ 382.57(a)
(a) As a carrier, you must comply with the following requirements with respect to any automated airport kiosk you own, lease, or control at a U.S. airport with 10,000 or more enplanements...
-
611.2 Clear Floor Space
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
232.5.2 Partitions
Where solid partitions or security glazing separate visitors from detainees or inmates, at least one of each type of cubicle or counter partition shall comply with 904.6....
-
1008.1.9.7, Item 5.1
5.1 A tactile sign shall also be provided in Braille and raised characters, which complies with Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5....
-
12145(a)(3)
that the public entity seeking temporary relief has made good faith efforts to locate a qualified manufacturer to supply the lifts to the manufacturer of such buses in sufficient time to comply...
-
605.1 General
Urinals shall comply with 605. Advisory 605.1 General. Stall-type urinals provide greater accessibility for a broader range of persons, including people of short stature....
-
§ 36.406(d)(1)
(1) In sleeping rooms with more than 25 beds covered by this section, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....
-
1002.5.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
-
802.2.1 Lines of Sight over Seated Spectators
Where spectators are expected to remain seated during events, spectators in wheelchair spaces shall be afforded lines of sight complying with 802.2.1....
-
304.3.1 Circular Space
The space shall be permitted to include knee and toe clearance complying with 306....