The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
Search Results "Clear Floor Area"
Commonly Searched Documents
-
11B-407.4.7.1.3 Symbols
-
M303.4.1 Breast Platform Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a mammography breast platform height range of 30 inches high minimum and 42 inches high maximum above the floor....
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
-
11B-411.2.3.2 Car designation signs
Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation....
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
Sec.36.401(d)(1)(ii)(B)
The facility housing a "shopping center or shopping mall'' only includes floor levels housing at least one sales or rental establishment, or any floor level designed or intended for use...
-
Car Position Indicators [§407.4.8]
Specifications include: ½” min. character height Illumination of each floor level passed or stopped at Automatic verbal announcement of stop or non-verbal audible...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
Altered Rides
An existing ride is also considered an altered ride if the load or unload area is newly designed or constructed....
-
3.4 Some Basic Principles of Reasonable Accommodation
For example: An employer provides an employee lunchroom with food and beverages on the second floor of a building that has no elevator....
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.5.2
Section 608.5.2 covers the current ADA Standards for controls in standard roll-in type shower compartments.
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.5.3
Section 608.5.3 covers the current ADA Standards for controls in alternate roll-in type shower compartments.
-
11B-217.4 TTYs
Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site....
-
907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
11B-809.8 Doors
The floor or landing at primary entry doors, required exit doors, and secondary exit doors where a change in elevation occurs between the interior and the exterior surface of the floor or...
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-708.4 Residential dwelling unit communication systems
Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with Section 11B-708.4....
-
f-ii
Is the change in level from the floor to the lift surface ramped or beveled? [ADA Standards §§ 4.11.2, 4.5.2] Yes No...