Search Results "Water Closet Clear Floor Space"
-
POWER DISRUPTION
-
REPAIR
The definition is clear that repair is limited to work on an item or part and does not apply to a renovation, rehabilitation or renovation to an existing building in the event of fire or...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-205.1 General
Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply with Section 11B-309. Exceptions: 1....
-
11B-205.1 General
Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply with Section 11B-309. Exceptions: 1. ...
-
11B.707.7.1.3 Horizontally mounted display screen
from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor...
-
4. Organization of Technical Criteria
space, and height of the breast platform....
-
11B-233.3.1.2.5 Public housing facility site impracticality
The remaining ground floor residential dwelling units shall comply with the following requirements: 1. Grab bar reinforcement complying with Section 11B-609. 2. ...
-
11B-810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2438 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
Section 36.406(g) Medical Care Facilities (Section-by-Section Analysis)
The Access Board decided not to add a dispersion requirement because compliance over the lifetime of the facility could prove difficult given the need for flexibility of spaces within such...
-
503.5 Vertical Clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide...
-
11B-812.8.1 Four or fewer
Where four or fewer total EVCS are provided, identification with an International Symbol of Accessibility (ISA) and signs identifying van accessible spaces shall not be required....
-
1009.5.1 Transfer Platform
Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width. ...
-
DRIVE-UP ELECTRIC VEHICLE CHARGING STATION
vehicle charging station in which use is limited to 30 minutes maximum and is provided at a location where the electric vehicle approaches in the forward direction, stops in the vehicle space...
-
Priorities for Accessible Facilities
Accessible approach and entrance Priority 2 - Access to goods and services Priority 3 - Access to public toilet rooms Priority 4 - Access to other items such as water...
-
Sinks [F212.3, Exception 2]
When hot water is provided, the drainpipes at sinks and lavatories must be wrapped, insulated, or shielded to help prevent a person using a mobility device from accidentally touching the...
-
Evaluation of transfers
Our results also showed that in terms of minimum space required for the transfer, the guidelines are insufficient (Table 12)....
-
11B.707.7.1.1 Vertically mounted display screen
mounted vertically or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
-
4.1.1(1)
(1) At least one accessible route complying with 4.3 shall be provided within the boundary of the site from public transportation stops, accessible parking spaces, passenger loading zones...
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-411.2.2.1 Visible identification
The identification fixture shall be 80 inches (2032 mm) minimum above the finish floor or ground to the bottom of the fixture....
-
C. Accessibility Within Toilet Rooms
Is at least one stall at least 60 inches wide and 56 inches deep (wall mounted toilet) or 59 inches deep (floor mounted toilet)?...