In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted....
Search Results "Shall"
-
1007.11 Instructions
-
F202.6 Leases
effective date of the revised standards issued pursuant to the Architectural Barriers Act, including new leases for buildings or facilities previously occupied by the Federal government, shall...
-
607.4.2.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub...
-
1008.4.3 Play Tables
Where play tables are provided, knee clearance 24 inches (610 mm) high minimum, 17 inches deep (430 mm) minimum, and 30 inches (760 mm) wide minimum shall be provided....
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....
-
602.2 Clear Floor Space
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be 1/2 inch (13 mm) high maximum in accordance with 303....
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....
-
904.4.1 Parallel Approach
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
207.1 General
Means of egress shall comply with section 1003.2.13 of the International Building Code (2000 edition and 2001 Supplement) or section 1007 of the International Building Code (2003 edition...
-
502.6 Identification
Parking space identification signs shall include the International Symbol of Accessibility complying with 703.7.2.1....
-
907.2.6 Group I
A manual fire alarm system and an automatic fire detection system shall be installed in Group I occupancies....
-
213.3.7 Coat Hooks and Shelves
Where coat hooks or shelves are provided in toilet rooms without toilet compartments, at least one of each type shall comply with 603.4....
-
12162(e)(2)(C) Required cooperation
(C) Required cooperation It shall be considered discrimination for purposes of section 12132 of this title and section 794 of title 29 for an owner, or person in control, of a station...
-
407.4.6.1 Location
Controls shall be located within one of the reach ranges specified in 308. EXCEPTIONS: 1....
-
11B-407.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308. Exceptions: 1. ...
-
406.8 Detectable Warnings
Curb ramps subject to Department of Transportation regulation 49 CFR 37.21 shall have a detectable warning complying with 705....
-
1007.7.2 Outdoor facilities
Every required exterior area of assisted rescue shall have direct access to an interior exit stairway, exterior stairway, or elevator serving as an accessible means of egress component....
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-232.5.1 Cubicles and counters
At least 5 percent, but no fewer than one, of cubicles shall comply with Section 11B-902 on both the visitor and detainee sides....
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device....
-
1133A.3 Removable base cabinets
Sinks and work surfaces required by Section 1133A.4 (see Item 1 and Item 2) shall be provided with a knee and toe space complying with Section 1133A.7....
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....