The requirement in the 1991 Standards that handrails extend horizontally at least 12 inches beyond the width of one tread at the bottom of a stair was changed in the 2004 ADAAG by the Access...
Search Results "One Step Entry"
-
Sections 505.10.2 and 505.10.3
-
4. Pressure Gauge
Either one will work as long as it is periodically checked for proper calibration in accordance with the manufacturer’s instructions....
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
Transfer Compartments
For example, a hotel with 100 guest rooms would be required to have at least 5 guest rooms that are accessible, one of which would have to provide a roll-in shower; the shower provided in...
-
Is it prohibited to draw majority-minority districts?
One such justification may be the need to remedy a violation of Section 2 of the Voting Rights Act....
-
703.4.2 Location
Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf....
-
1127B.5, Item 4
provided at the upper end of each curb ramp over its full width to permit safe egress from the ramp surface, or the slope of the fanned or flared sides of the curb ramp shall not exceed one...
-
Teeing Grounds
Multiple Teeing Grounds—If one or two teeing grounds are provided for a hole, only the forward teeing ground must be accessible either by an accessible route or a golf car passage....
-
11B-202 Existing buildings and facilities
., Section 36.304) or the accessibility requirements of this code as those requirements or regulations now exist or are hereafter amended consisting of one or more of the following items...
-
Notes:
The concept of technical feasibility is one found in other areas of access. ...
-
3. Do requests for reasonable accommodation need to be in writing?
Employers, however, must keep all employment records, including records of requests for reasonable accommodation, for one year from the making of the record or the personnel action involved...
-
Orientation (slide 12)
But there are a lot of buildings where [separation is provided by] an area rug or a change of floor color: “that’s the furnished area that’s [the waiting area] right adjacent or to one side...
-
REASONABLE ACCOMMODATION RELATED TO THE BENEFITS AND PRIVILEGES OF EMPLOYMENT
The discussions and examples in this section assume that there is only one effective accommodation and that the reasonable accommodation will not cause undue hardship....
-
Implementation Challenges for Interiors (slides 16 and 17)
Comments by [three Participants]: There’s one other aspect of the detectable warnings that people don’t think about....
-
C. Examples of Recipients Covered by These Guidelines
The administrative board of a specialized vocational high school serving students from more than one school district. 3....
-
907.2.9 Group R-2
installed in Group R-2 occupancies where: Any dwelling unit is located three or more stories above the lowest level of exit discharge; Any dwelling unit is located more than one...
-
D. Recording, Categorizing, and Reporting Written Disability-related Complaints Received by Carriers
Certificated U.S. carriers and foreign carriers1 operating to, from, and in the United States using at least one aircraft with more than 60 passenger seats must record, categorize, and report...
-
3. Temporary Solutions for Emergency Sheltering - Parking
At least one accessible parking space should be a van-accessible parking space with an access aisle that is at least 96 inches wide....
-
Showers
The final Guidelines for usable bathrooms (the first set of specifications) specify size dimensions for shower stalls in only one situation -- when the shower stall is the only bathing facility...
-
2. Section-by-Section Analysis of Final Guidelines
The following section-by-section analysis discusses the comments received on each of the sections of the proposed Option One Guidelines, and the Department's response to these comments....
-
In-swinging Bathroom Doors
One commenter stated that in-swinging bathroom doors generally are problematic, unless the bathroom is unusually large....
-
§8.29 Homeownership programs (sections 235(i) and 235(j), Turnkey III and Indian housing mutual self-help programs).
If accessibility features selected at the option of the homebuyer are ones covered by the standards prescribed by §8.32, those features shall comply with the standards prescribed in §8.32...
-
Universal Design in Practice
. • One Perimeter Park So, Suite 200S • Birmingham AL 35243 • Phone 205/9729100 • TTY 205/9729112 • Fax 205/9729110 www.evanterry.com • email: eta@evanterry.com...
-
703.4.2 Location
Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf....