During construction inspection finish product thicknesses such as flooring materials or wall coverings must be considered when reviewing critical accessibility features, including but not...
Search Results "Shower Clear Floor Space"
-
CASI Accessibility Construction Inspection Checklist
-
CALBO Accessibility Construction Inspection Checklist
During construction inspection finish product thicknesses such as flooring materials or wall coverings must be considered when reviewing critical accessibility features, including but not...
-
1.17 Unobstructed view
is not blocked or interfered with by any seats, railings, or other objects and is configured to have visual clearance over average height patrons seated one row ahead of the wheelchair spaces...
-
7.4.9 Trail Facilities
When the surface of the required clear ground space for trail facilities is not paved or is not elevated above the natural ground, slopes not steeper than 1:20 (5 percent) shall be permitted...
-
1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
306.2.4 Additional Clearance
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
-
DIVISION 8: SPECIAL ROOMS, SPACES AND ELEMENTS
[See subsections ...]
-
A4.26.2 Size and Spacing of Grab Bars and Handrails
This specification allows for alternate shapes of handrails as long as they allow an opposing grip similar to that provided by a circular section of 1‒1/4 in to 1‒1/2 in (32 mm to 38...
-
A4.26.2 SIZE AND SPACING OF GRAB BARS AND HANDRAILS
This specification allows for alternate shapes of handrails as long as they allow an opposing grips similar to that provided by a circular section of 1-1/4 in to 1-1/2 in (32 mm to...
-
ADA Compliance BRIEF: Restriping Parking Spaces
U.S. Department of Justice Civil Rights Division Disability Rights Section
-
DIVISION 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
[See subsections ...]
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
Transfer Platform: ADA Standard Section 1009.5.1
Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
604.8.1.1 Size
shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor...
-
604.8.1.1 Size
shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor...
-
604.8.1.1 Size
shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor...
- Bradley Aerix+ High Speed, Stainless Steel Vertical Dual-Sided Hand Dryer
- Magnuson Group WH Hanger Style Wall Rack
- Bradley Aerix+ High Speed Vertical Dual-Sided Hand Dryer
-
11B-805.7 Built-in cabinets and work surfaces
A 30-inch by 48-inch clear floor space, in compliance with Section 11B-305, shall be centered in front of the display screen. ...