Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
Search Results "Clear Floor Area"
-
11B-604.9.5 Flush controls
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
11B-405.9.1 Reserved
[2010 ADAS] 405.9.1 Extended Floor or Ground Surface. ...
-
11B-405.9.1 Reserved.
[2010 ADA Standards] 405.9.1 Extended Floor or Ground Surface....
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum....
-
F - number system
F - number system The F - number system, ASTM E 1155, Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers, was developed primarily to aid in the construction...
-
217.4.2.1 Public Buildings
Where at least one public pay telephone is provided on a floor of a public building, at least one public TTY shall be provided on that floor....
-
217.4.2.2 Private Buildings
Where four or more public pay telephones are provided on a floor of a private building, at least one public TTY shall be provided on that floor....
-
Accessible Fishing Piers and Platforms
If railings, guards, or handrails are provided, accessible edge protection and clear floor or ground space at accessible railings are required....
-
Kitchen Appliances
Section 309 includes specifications for clear floor space (309.2), height (309.3), and operating characteristics (309.4)....
-
Automated Revolving Doors
automated revolving doors, in order to be wheelchair accessible, must have a diameter of at least 10 to 12 feet depending on the number of compartments so that each compartment provides clear...
-
Accessible Means of Egress
A continuous and unobstructed way of egress travel from any point in a building or facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way....
-
Overhead Lifts
Overhead lifts and portable floor lifts are used in health care facilities, and the technical criteria should not be viewed as preferring portable floor lifts....
-
11B-1009.2.6 Footrests and armrests
The armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised position. [2010 ADAS] 1009.2.6 Footrests and Armrests. ...
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
-
11B-1009.2.6 Footrests and armrests
The armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised position. [2010 ADAS] 1009.2.6 Footrests and Armrests....
-
11B-304.3.2 T-Shaped space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
11B-304.3.2 T-Shaped space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....