The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
Search Results "Wet Bar"
-
11B-604.7 Dispensers and disposal units
-
609.2.2 Non-Circular Cross Section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
-
609.2.2 Non-Circular Cross Section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
Error/Omission: Toilet rooms with 6 or more toilet stalls lack a 36" wide "ambulatory" toilet stall.
People who walk with crutches, a cane, a walker, or who have limited balance generally find it easier and safer to use a stall that has parallel grab bars....
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
Clear Deck Space
If there is one grab bar on a transfer wall, the clear deck space must be centered on the one grab bar. That allows enough space for a transfer on either side of the bar....
-
1134A.6, Item 4
Reinforced walls for grab bars. Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
1009.4.1 Clear Deck Space
Where one grab bar is provided, the clear deck space shall be centered on the grab bar....
-
1134A.6, Item 4
Reinforced walls for grab bars. Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
11B-1009.4.1 Clear deck space
Where one grab bar is provided, the clear deck space shall be centered on the grab bar....
-
11B-1009.4.1 Clear deck space
Where one grab bar is provided, the clear deck space shall be centered on the grab bar....
-
K. Ambulatory Stall
If there are more than 5 stalls in any restroom, is there one stall in addition to the large accessible stall, that is 36" wide, has 2 parallel grab bars at 33"-36" off the floor and has...
-
1009.4.1 Clear Deck Space
Where one grab bar is provided, the clear deck space shall be centered on the grab bar....
-
11B-1009.4.1 Clear deck space
Where one grab bar is provided, the clear deck space shall be centered on the grab bar....
-
1009.4.1 Clear Deck Space
Where one grab bar is provided, the clear deck space shall be centered on the grab bar....
-
C. Food Service
.: direct counter service) at counters or bars, is there a minimum 60" long portion providing a 27" high knee space, at least 19" deep, with the counter top at 28"-34" above the floor, or...
-
607.4.1 Bathtubs with Permanent Seats
For bathtubs with permanent seats, grab bars shall be provided in accordance with 607.4.1. Figure 607.4.1 Grab Bars for Bathtubs with Permanent Seats...
-
607.4.2 Bathtubs without Permanent Seats
For bathtubs without permanent seats, grab bars shall comply with 607.4.2. Figure 607.4.2 Grab Bars for Bathtubs with Removable In-Tub Seats...
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall....
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall....
-
F248 Beach Access Routes
[See subsections ...]
-
1018 Beach Access Routes
[See subsections ...]
-
Technical Requirements [1018 and 1018.1, Exception 3]
The technical requirements for beach access routes include specific provisions for connections, the surface, clear width, obstacles, openings, running slope, cross slope, resting...