Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
- 
    
  
  11B-305.7.2 Parallel approach
  
- 
    
  
  305.7.2 Parallel Approach
  Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach 
- 
    
  
  305.7.1 Forward Approach
  Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach 
- 
    
  
  305.7.1 Forward Approach
  305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove,... 
- 
    
  
  305.7.2 Parallel Approach
  Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). 
- 
    
  
  305.7.1 Forward Approach
  Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). 
- 
    
  
  11B-305.7.1 Forward approach
  Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm). FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH 
- 
    
  
  305.7.2 Parallel Approach
  305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove,... 
- 
    
  
  305.7.1 Forward Approach
  Alcoves shall be 36 inches (915 mm)wide minimum where the depth exceeds 24 inches (610 mm). 
- 
    
  
  305.7.2 Parallel Approach
  Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). 
- 
    
  
  11B-305.7.1 Forward approach
  Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm). 
- 
    
  
  11B-305.7.2 Parallel approach
  Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). 
- 
    
  
  11B-305.7.1 Forward approach
  Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm). 
- 
    
  
  11B-305.7.2 Parallel approach
  Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). 
- 
    
  
  Floor Surfaces: ADA Standard Section 409.4.2
  Section 409.4.2 covers the current ADA Standards for the floor surfaces of private residence elevator cars. 
- 
    
  
  604.3 Clearance
  Clearances around water closets and in toilet compartments shall comply with 604.3. 
- 
    
  
  604.3.1 Size
  Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear... 
- 
    
  
  604.3 Clearance
  Clearances around water closets and in toilet compartments shall comply with 604.3. 
- 
    
  
  604.3.1 Size
  Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear... 
- 
    
  
  604.3.1 Size
  604.3.1 Size. Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular... 
- 
    
  
  604.3 Clearance
  604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with 604.3. 
- 
    
  
  11B-604.3 Clearance
  Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3. 
- 
    
  
  604.3 Clearance
  Clearances around water closets and in toilet compartments shall comply with 604.3. 
- 
    
  
  604.3.1 Size
  Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear... 