Where emergency warning systems are provided, fire alarms shall comply with Section 11B-702 and carbon monoxide alarms shall comply with Chapter 4. [2010 ADA Standards] 806.3.1...
Search Results "Place of Lodging"
Commonly Searched Documents
-
11B-806.3.1 Alarms
-
Accessible Routes - Interior and Exterior
., hallways and corridors) throughout the lodging facility, are not usable by persons who use wheelchairs or other mobility aids, or who are unable to climb steps or stairs....
-
§ 36.402(b)(1)
(1) Alterations include, but are not limited to, remodeling, renovation, rehabilitation, reconstruction, historic restoration, changes or rearrangement in structural parts or...
-
Problem Four
Problem Four: No sign with the International Symbol of Accessibility is installed at each accessible parking space. Solution: Provide a temporary sign in front of each accessible...
-
Problem Three
Problem Three: Accessible parking spaces or access aisles are on a sloped surface and do not provide a level area for a safe transition from the voter’s car to a...
-
Problem Two (Accessible Route)
Problem Two: The accessible route crosses a curb and no curb ramp is provided. Solution: Install a portable ramp.
-
Problem Four (Entrance)
Problem Four: The entrance door has a door knob and/or latch that requires tight pinching and twisting and is not accessible. Solution: There are four typical solutions: add an...
-
12204(c) Qualified Historic Properties
(c) Qualified Historic Properties. --
-
12204(c) Qualified historic properties
(c) Qualified historic properties
-
Sec.36.402(b)(1)
(1) Alterations include, but are not limited to, remodeling, renovation, rehabilitation, reconstruction, historic restoration, changes or rearrangement in structural parts or...
-
C2-2. Undersides of Exterior Stairs
C2-2. Are the undersides of exterior stairs enclosed or protected with a cane detectable barrier so that people who are blind or have low vision will not hit their heads on the...
-
A2. Access Aisle
A2. Does each accessible parking space have its own, or share an adjacent access aisle that is least 60 inches (5 feet) wide? [ADA Stds 4.6.3] Yes _____ No _____
-
4d.
4d. If a ramp is more than 30 feet long, is a level landing at least 60 inches long provided every 30 feet of horizontal length? [ADA Stds 4.8.4] Yes _____ No _____ Note: When...
-
Temporary Solutions for Election Day
Temporary Solutions for Election Day Passenger Drop-Off Areas
-
Problem Three
Problem Three: Accessible parking spaces or access aisles are on a sloped surface. Suggestion: Find a parking area that is close to the accessible entrance and more level....
-
A7. Curb Ramps
A7. If there is a curb between the access aisle and the accessible route to the building, is there a curb ramp that meets the following requirements: [ADA Stds 4.7] a. Is the ramp...
-
B4. Vertical Clearance
B4. Is the vertical height for the vehicle route to the loading zone, the drop off area, and the exit at least 114 inches (9 feet 6 inches) in height? [ADA Stds 4.6.5] Yes _____...
-
224.6.1 Guest rooms
224.6.1 Guest rooms. Guest rooms with mobility features shall be provided as follows: (i) Facilities that are subject to the same permit application on a common site that each have...
-
Overlapping Wheelchair Turning Space
A provision in section 806.2.6 prohibiting beds from overlapping wheelchair turning space has been removed for consistency with specifications for such space in section 304, as...
-
Communication
Hotel team members who have direct contact with guests should be prepared and ready to communicate with customers with disabilities. When telephone calls are received from a deaf...
-
K. Operable Parts
K. Are the drapery wands and controls on fixed lamps and HVAC units easily operable with one hand, without tight grasping, pinching or twisting of the wrist, since many persons with...
-
I. Parking and Loading Zone...
[See subsections ...]
-
A. Entry Doors
A. Do entry doors, connecting room doors, and interior doors (except doors to shallow closets) into and within all guestrooms and suites allow 32" clear passage width so persons who...
-
H. Door Maneuvering Clearance
H. On the pull side of each door (i.e.: entry door, connecting room door, bathroom doors and other passage doors) in every accessible guestroom/suite, are there at least 18" of clear...