In order for an accessible parking space to be usable, all elements of the space must be free of obstructions: the vehicle space, the access aisle, the curb ramp, and the route that...
Search Results "Obstruction"
Commonly Searched Documents
-
Accessible Parking
-
2. Armrests Requirement
The MDE Advisory Committee recommended that armrests not be required, but if provided they cannot obstruct transfer supports....
-
R410.6 Character Height
Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further approach towards the sign....
-
11B-604.8.1.1 Size
This space cannot be obstructed by baby changing tables or other fixtures or conveniences, except as specified at 604.3.2 (Overlap)....
-
Comments
A number of commenters expressed concern about the provision of the NPRM saying that mini-high platforms and other platform obstructions should be at least six feet back from the platform...
-
Attachment J
All spaces designated as reserved for persons with disabilities shall have vertical signs with the International Symbol of Accessibility located such that they cannot be obstructed by parked...
-
11B-604.8.1.2 Doors
including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door side of the compartment and any obstruction...
-
Plan 3A: 12-Foot Wide Accessible Guest Room
clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions...
-
Plan 4B: 13-Foot Wide Accessible Guest Room
clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions...
-
Plan 6A: 12-Foot Wide Accessible Guest Room
closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16 inches from side wall (section 604.2); and • No other fixtures or obstructions...
-
Plan 3B: 12-Foot Wide Accessible Guest Room
clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions...
-
Plan 1A: 13-Foot Wide Accessible Guest Room
clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions...
-
Plan 1B: 13-Foot Wide Accessible Guest Room
clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions...
-
Plan 2A: 13-Foot Wide Accessible Guest Room
clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions...
-
Plan 2B: 13-Foot Wide Accessible Guest Room
clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions...
-
Sides of Curb Ramps
This exception was provided to address situations where existing space constraints or obstructions may prohibit a landing at the top of curb ramps....
-
Maintenance of Accessible Features
Inoperable elevators, locked accessible doors, routes that are obstructed by furniture are neither "accessible to" nor "usable by" people with disabilities....
-
Location and Spacing
serve some large rooms or corridor sections with a single appliance located on a perimeter wall or suspended below the ceiling so that the signal can spread throughout the space without obstruction...
-
11B-703.4.2 Location
Exception: In alterations where sign installation locations identified in Section 11B-703.4.2 are obstructed or otherwise unavailable for sign installation, signs with tactile characters...
-
11B-604.8.1.2 Doors
including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door side of the compartment and any obstruction...
-
11B-604.8.1.2 Doors
including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door side of the compartment and any obstruction...
-
11B-608.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
Plan 4A: 13-Foot Wide Accessible Guest Room
clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions...