In order for an accessible parking space to be usable, all elements of the space must be free of obstructions: the vehicle space, the access aisle, the curb ramp, and the route that...
Search Results "Obstruction"
Commonly Searched Documents
- 
    
  
  Accessible Parking
  
- 
    
  
  2. Armrests Requirement
  The MDE Advisory Committee recommended that armrests not be required, but if provided they cannot obstruct transfer supports.... 
- 
    
  
  R410.6 Character Height
  Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further approach towards the sign.... 
- 
    
  
  11B-604.8.1.1 Size
  This space cannot be obstructed by baby changing tables or other fixtures or conveniences, except as specified at 604.3.2 (Overlap).... 
- 
    
  
  Comments
  A number of commenters expressed concern about the provision of the NPRM saying that mini-high platforms and other platform obstructions should be at least six feet back from the platform... 
- 
    
  
  Attachment J
  All spaces designated as reserved for persons with disabilities shall have vertical signs with the International Symbol of Accessibility located such that they cannot be obstructed by parked... 
- 
    
  
  11B-604.8.1.2 Doors
  including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door side of the compartment and any obstruction... 
- 
    
  
  Plan 3A: 12-Foot Wide Accessible Guest Room
  clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions... 
- 
    
  
  Plan 4B: 13-Foot Wide Accessible Guest Room
  clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions... 
- 
    
  
  Plan 6A: 12-Foot Wide Accessible Guest Room
  closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16 inches from side wall (section 604.2); and • No other fixtures or obstructions... 
- 
    
  
  Plan 3B: 12-Foot Wide Accessible Guest Room
  clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions... 
- 
    
  
  Plan 1A: 13-Foot Wide Accessible Guest Room
  clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions... 
- 
    
  
  Plan 1B: 13-Foot Wide Accessible Guest Room
  clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions... 
- 
    
  
  Plan 2A: 13-Foot Wide Accessible Guest Room
  clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions... 
- 
    
  
  Plan 2B: 13-Foot Wide Accessible Guest Room
  clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions... 
- 
    
  
  Sides of Curb Ramps
  This exception was provided to address situations where existing space constraints or obstructions may prohibit a landing at the top of curb ramps.... 
- 
    
  
  Maintenance of Accessible Features
  Inoperable elevators, locked accessible doors, routes that are obstructed by furniture are neither "accessible to" nor "usable by" people with disabilities.... 
- 
    
  
  Location and Spacing
  serve some large rooms or corridor sections with a single appliance located on a perimeter wall or suspended below the ceiling so that the signal can spread throughout the space without obstruction... 
- 
    
  
  11B-703.4.2 Location
  Exception: In alterations where sign installation locations identified in Section 11B-703.4.2 are obstructed or otherwise unavailable for sign installation, signs with tactile characters... 
- 
    
  
  11B-604.8.1.2 Doors
  including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door side of the compartment and any obstruction... 
- 
    
  
  11B-604.8.1.2 Doors
  including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door side of the compartment and any obstruction... 
- 
    
  
  11B-608.6 Shower spray unit and water
  If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars.... 
- 
    
  
  Plan 4A: 13-Foot Wide Accessible Guest Room
  clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and • No other fixtures or obstructions... 