The Guidelines for Requirement 4 present design specifications for providing an accessible route into and through the covered dwelling unit, as required by §100.205(c)(3)(i)....
Search Results "Multi-Story Residential Dwelling Unit"
-
Guidelines for Requirement 4
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
11B-203.9 Employee workstations
Employee workstations shall be on an accessible route complying with Division 4. Spaces and elements within employee workstations shall only be required to comply with Sections...
-
11B-203.9 Employee workstations
Employee workstations shall be on an accessible route complying with Division 4. Spaces and elements within employee workstations shall only be required to comply with Sections...
-
608.3 Grab Bars (Exception 2)
608.3 Grab Bars (Exception 2) Exception 2 to this section permits grab bars to not be installed in shower compartments in residential dwelling units required to provide mobility features...
-
607.4 Grab Bars (Exception 2)
607.4 Grab Bars (Exception 2) Exception 2 to this section permits grab bars to not be installed at bathtubs in residential dwelling units required to provide mobility features provided...
-
804.3 Kitchen Work Surface
In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3....
-
804.3 Kitchen Work Surface
In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3....
-
11B-233.3.4 Alterations
Clarifies in the exception the technical requirements for accessible residential dwelling units when alterations are made to existing public housing facilities are technically infeasible...
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 shall be permitted in multi-story residential dwelling units....
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 shall be permitted in multi-story residential dwelling units....
-
(b) Multistory dwelling units in buildings with elevators
For multistory dwelling units in buildings with elevators, the final Guidelines specify that only the story served by the building elevator must comply with the accessible features for dwelling...
-
1130A.1 General
An accessible route shall be provided through all rooms and spaces of the dwelling unit....
-
1130A.1 General
An accessible route shall be provided through all rooms and spaces of the dwelling unit....
-
11B-809.10.6.3 Clearance
From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle": "Amendments increase clear floor space at showers in residential...
-
1130A.1 General
An accessible route shall be provided through all rooms and spaces of the dwelling unit....
-
233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations
233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations....
-
804.3 Kitchen Work Surface
In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3....
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
Story
If such portion of a building does not include occupiable space, it is not considered a story for purposes of these guidelines....
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...