Vehicle spaces, access aisles serving them, and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum....
Search Results "Hoistway Clearance"
Commonly Searched Documents
-
11B-812.4 Vertical clearance
-
404.3.2 Maneuvering Clearance
Clearances at power-assisted doors and gates shall comply with 404.2.4....
-
404.3.2 Maneuvering Clearance
Clearances at power-assisted doors and gates shall comply with 404.2.4....
-
Clear Width of Circulation Paths and Maneuvering Clearances at Wheelchair Spaces
., “sufficient clearances”) with quantified minimum clearances, nonetheless expressed some skepticism that such clearances would be adequate to accommodate all types of mobility devices,...
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided. Exceptions: 1....
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
Can maneuvering for a forward approach be provided when there is space at least 60” deep in front of a door?
Space at least 60” deep in front of a door that is unobstructed on approach sides will provide sufficient depth for a forward approach if appropriate strike-side clearance is provided; but...
-
M303.2.4.2.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum measured from the toe end of the wheelchair...
-
1011.4.2 Wheelchair Space
Wheelchair spaces shall be positioned for a forward approach to the table and provide knee and toe clearance complying with 306 under the table....
-
1011.4.2 Wheelchair Space
Wheelchair spaces shall be positioned for a forward approach to the table and provide knee and toe clearance complying with 306 under the table....
-
A4.6.5 Vertical Clearance
High-top vans, which disabled people or transportation services often use, require higher clearances in parking garages than automobiles....
-
H. Door Maneuvering Clearance
H. On the pull side of each door (i.e.: entry door, connecting room door, bathroom doors and other passage doors) in every accessible guestroom/suite, are there at least 18" of clear...
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
Approach and Maneuvering Clearance [§305.6 and §305.7]
Approach and Maneuvering Clearance [§305.6 and §305.7] Where the space is obstructed on both sides for more than half the depth, additional clearance is required for maneuvering....
-
Inventory Control Devices
Inventory Control Devices It is important that inventory control or security devices not obstruct required maneuvering clearances at doors....
-
Clear Floor Space [4.20.2]
ADAAG allows a lavatory on the same plumbing wall to overlap the clear floor space at the tub because knee and toe clearance is available below an accessible lavatory....
-
Figure M6: M303.2.4 Knee and Toe Clearance
[See subsections ...]
-
11B-809.9.3 Removable base cabinets
Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4. Exception: Removable base cabinets...
-
Handrail Clearance and Cross Section [§505.5, §505.7]
Handrail Clearance and Cross Section [§505.5, §505.7] Surface requirements and clearances facilitate a power grip along the length of handrails....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....