Search Results "Ground Floor Exit"
-
11B-306.3.3 Minimum required depth
-
1007.2.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1003.2.13.1.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
11B-306.3.3 Minimum required depth
or ground, and 8 inches (203 mm) deep minimum at 27 inches (686 mm) above the finish floor or ground. ...
-
11B-306.3.3 Minimum required depth
or ground, and 8 inches (203 mm) deep minimum at 27 inches (686 mm) above the finish floor or ground....
-
804.6.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
-
804.6.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
- Walk-A-Sured Roll-On Anti-Slip Safety Coating System
- Miracle Sealant Company 511 Anti-Slip Formula
- Walk-A-Sured Clear Anti-Slip Safety Coating System
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or code that require the lowest floor...
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or code that require the lowest floor...
-
Re: ADA Sign Products Exit Sign (6" x 3")
Product link is broken adasignproducts.goemerchant-stores.com
-
Teeing Ground
Teeing Ground. In golf, the starting place for the hole to be played....
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
Minimum Number and Types: ADA Standard Section 240.2.1.1
Section 240.2.1.1 covers scoping requirements in the current ADA Standards for minimum number and types of ground level play components.
-
TEEING GROUND
TEEING GROUND. [DSA-AC] In golf, the starting place for the hole to be played....
-
Ground Level Play Component
Ground Level Play Component. A play component that is approached and exited at the ground level....
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
Sites where either Test No. 1 or Test No. 3 is used and it is determined that an accessible route to the common (lobby) entrance is not required, a minimum of 20 percent of the ground floor...
-
11B-1004.1 Clear floor space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 11B-1004.1 Clear floor space....
-
11B-1004.1 Clear floor space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 11B-1004.1 Clear floor space....
-
GROUND LEVEL PLAY COMPONENT
GROUND LEVEL PLAY COMPONENT. [DSA-AC] A play component that is approached and exited at the ground level....
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...