Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
Search Results "Ground Floor"
-
11B-305.7.2 Parallel approach
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm).
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
305.7.1 Forward Approach
305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove,...
-
305.7.2 Parallel Approach
305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove,...
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....
-
Ground-Level Play Components
Ground-Level Play Components There are two requirements addressing how many ground-level play components must be on an accessible route: One of Each Type Ground-Level...
-
11B-502.4 Floor or ground surfaces
Advisory 11B-502.4 Floor or ground surfaces. Access aisles are required to be nearly level in all directions to provide a surface for wheelchair transfer to and from vehicles....
-
11B-502.4 Floor or ground surfaces
Advisory 11B-502.4 Floor or ground surfaces. Access aisles are required to be nearly level in all directions to provide a surface for wheelchair transfer to and from vehicles....
-
Ground Level Play Component
Ground Level Play Component - A play component that is approached and exited at the ground level....
-
Overlap: ADA Standard Section 603.2.2
Section 603.2.2 covers the current ADA Standards for overlapping clear floor space at fixtures and turning spaces in toilet and bathing rooms.
-
804.3.1 Clear Floor or Ground Space
804.3.1 Clear Floor or Ground Space. A clear floor space complying with 305 positioned for a forward approach shall be provided....
-
Door Swing: ADA Standard Section 603.2.3
Section 603.2.3 covers the current ADA Standards for door swings at clear floor space and clearances at fixtures in toilet and bathing rooms.
-
TEST NO. 2 – SITE ANALYSIS TEST
In no case shall less than 20 percent of the ground floor dwelling units be on an accessible route and comply with the provisions of Division IV. 3. ...
-
4) Where the Standard is silent about changes in level
4) Where the Standard is silent about changes in level, such as 604.3 around a water closet or in a toilet compartment: Since there is no mention of the phrase "changes in level...
-
Accessible - Changes in Level
Accessible - Changes in Level: Changes in level up to 1/4" may be vertical and without edge treatment. Changes in level between 1/4" and 1/2" shall be beveled with a slope no...
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
- PEMKO 6 1/8" Floor Plates/Safety Treads No. 193
- PEMKO 6-1/8" Floor Plates/Safety Treads No.19325
- PEMKO 5 29/32" Floor Plates/Safety Treads No. 2266
- PEMKO 9 1/2" Floor Plates/Safety Treads No. 2286
-
4.5.6 Openings
Openings in the clear floor or ground space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
-
Can doors swing into required clear floor or ground space?
Doors cannot swing into required clear floor or ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates (404.3.5...
- Inpro Corporation JointMaster® 925 Fire Barrier System Expansion Joint Systems