Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with Section 11B-806.2 or residential dwelling units...
Search Results "Dwelling (FHA)"
-
11B-206.7.6 Guest rooms and residential dwelling units
-
11B-206.7.6 Guest rooms and residential dwelling units
Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with Section 11B-806.2 or residential dwelling units...
-
11B-206.7.6 Guest rooms and residential dwelling units
Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with Section 11B-806.2 or residential dwelling units...
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
11B-208.2.3.1 Parking for residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with Section 11B-502 shall be provided for each residential dwelling...
-
11B-208.2.3.1 Parking for residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with Section 11B-502 shall be provided for each residential dwelling...
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
General: ADA Standard Section 229.1
Section 229.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for windows.
-
§8.26 Distribution of accessible dwelling units.
Accessible dwelling units required by §8.22, 8.23, 8.24 or 8.25 shall, to the maximum extent feasible and subject to reasonable health and safety requirements, be distributed throughout...
-
F208.2.3.1 Parking for Residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with 502 shall be provided for each residential dwelling unit required...
-
208.2.3.1 Parking for Residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with 502 shall be provided for each residential dwelling unit required...
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
208.2.3.1 Parking for Residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with 502 shall be provided for each residential dwelling unit required...
-
11B-208.2.3.1 Parking for residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with Section 11B-502 shall be provided for each residential dwelling...
-
11B-229.1 General
Exception: Glazed openings in residential dwelling units required to comply with Section 11B-809 shall not be required to comply with Section 11B-229....
-
11B-229.1 General
Exception: Glazed openings in residential dwelling units required to comply with Section 11B-809 shall not be required to comply with Section 11B-229....
-
11B-708.4.2 Residential dwelling unit interface
11B-708.4.2 Residential dwelling unit interface....
-
708.4.2 Residential Dwelling Unit Interface
The residential dwelling unit system interface shall include a telephone jack capable of supporting voice and TTY communication with the common use or public use system interface....
-
708.4.2 Residential Dwelling Unit Interface
The residential dwelling unit system interface shall include a telephone jack capable of supporting voice and TTY communication with the common use or public use system interface....
-
9. I do not need to provide access to my rental office because I do not have disabled tenants in my housing facility.
All common use areas serving covered multifamily dwellings are also subject to the accessibility requirements in Chapter 11A, and the accessibility and reasonable accommodations requirements...
-
11B-233.3.1.2.1 Elevator buildings
Residential dwelling units on floors served by an elevator shall be adaptable....
-
11B-233.3.1.2.1 Elevator buildings
Residential dwelling units on floors served by an elevator shall be adaptable....