Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610....
Search Results "Lavatory Clear Floor Space"
-
805.4 Toilet and Bathing Rooms
-
1133A.3 Removable base cabinets
Sinks and work surfaces required by Section 1133A.4 (see Item 1 and Item 2) shall be provided with knee and toe space complying with Section 1133A.7....
-
Story
That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above....
-
11B-810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2438 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
11B-805.7 Built-in cabinets and work surfaces
A 30-inch by 48-inch clear floor space, in compliance with Section 11B-305, shall be centered in front of the display screen....
-
Accessible Plumbing Fixtures
The Board has added clarification that at least one water closet, lavatory, and bathtub or shower, where provided, must be accessible (807.2.4)....
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
Diagonal Curb Ramps
These curb ramps must have a 48 inch minimum clear space at the bottom....
-
1133B.2.4.2
SECTION 1133B GENERAL ACCESSIBILITY FOR ENTRANCES, EXITS AND PATHS OF TRAVEL 1133B.2 Doors. 1133B.2.4 Floor level at doors. ...
-
2.2.4 Maneuverability
The tasks were performed in restricted space conditions with the maneuvering performed within the confines of temporary barriers that are made of cardboard....
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
Raised and Braille Characters on Hoistway Entrances [4.10.5]
Raised and Braille floor designations are required on both jambs, with the centerline 60 inches from the finished floor. Raised characters must be 2 inches high....
-
1132A.4, Item 2
Exterior landings of pervious construction (e.g., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½...
-
1132A.4, Item 2
Exterior landings of pervious construction (e.g., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½...
-
4.30.6 Mounting Location and Height
Where permanent identification is provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....
-
25.1 Q. It appears from Figure 2(c) of the Guidelines (under Requirement 5) that there is a 34 inch height requirement for kitchen counters and vanities. Is this true?
Requirement 7 addresses the requirement for usable kitchens and bathrooms so that a person in a wheelchair can maneuver about the space....
-
Technical Requirements for Accessible Hiker/Pedestrian Trails
Section 7.4 of FSTAG explains the accessibility requirements for trails, including trail surfacing, clear tread width, grade and cross slope, resting intervals, passing spaces, tread obstacles...
-
Unisex Toilet Rooms
Unisex toilet rooms must have a lavatory and privacy latch and cannot have more than two toileting fixtures (i.e., two water closets, or one water closet and one urinal)....
-
Tent Pads and Tent Platforms [1013]
Tent pads and tent platforms are defined spaces with prepared surfaces for setting up and securing tents....
-
III-5.4200 Professional office of a health care provider
ILLUSTRATION: A physician has offices on the first floor of a multistory building. The second floor has other types of offices. An elevator is not required....
-
11B-406.5.10 Diagonal curb ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway....
-
Where Platform Lifts are Permitted [§206.7]
In new construction, platform lifts can be used to provide an accessible route to these areas only: wheelchair spaces, performance areas, and speakers’ platforms incidental...
-
208.2 Minimum Number
Where more than one parking facility is provided on a site, the number of accessible spaces provided on the site shall be calculated according to the number of spaces required for each parking...