[DSA-AC] A surfaced pedestrian way contiguous to a street used by the public. (As differentiated from the definition of “Walk”.) Advisory Definition of SIDEWALK. ...
Search Results "Hybrid Surface System"
-
SIDEWALK
-
405.9.2 Curb or Barrier
curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or ground surface...
-
405.9.2 Curb or Barrier
curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or ground surface...
-
7.4.6 Tread Obstacles
Where the trail surface is paved or is elevated above the natural ground, tread obstacles shall not exceed ½ inch (13 mm) in height measured vertically to the highest point. ...
-
R406.2 Unobstructed Forward Reach
Where a forward reach is unobstructed, the high forward reach shall be 1220 mm (4.0 ft) maximum and the low forward reach shall be 380 mm (1.25 ft) minimum above the finish surface....
-
Check-Out Areas [8.3]
Check-Out Areas [8.3] Check-out counters at accessible lanes are held to a maximum surface height of 36 inches....
-
4.7.5 Openings
Openings in surface of the clear floor or ground spaces required by section 2.0 shall not allow passage of a sphere more than 1/2 inch (13 mm) in diameter....
-
WALK
[DSA-AC] An exterior prepared surface for pedestrian use, including pedestrian areas such as plazas and courts. (As differentiated from the definition of “Sidewalk”.)...
-
M303.2.6 Edge Protection
Where wheelchair spaces are provided on a platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform...
-
WALK
[DSA-AC] An exterior prepared surface for pedestrian use, including pedestrian areas such as plazas and courts. (As differentiated from the definition of “Sidewalk”.)...
-
11B.707.7.1.2 Angle-mounted display screen
viewer 30 degrees to less than 60 degrees from vertical, the center line of the display screen and other display devices shall be no more than 44 inches (1118 mm) above the floor or ground surface...
-
1009.7.2 Separation
Exception: The fire-resistance rating and opening protectives are not required in the exterior wall where the building is equipped throughout with an automatic sprinkler system installed...
-
1009.7.2 Separation
Exception: The fire-resistance rating and opening protectives are not required in the exterior wall where the building is equipped throughout with an automatic sprinkler system installed...
-
Roughness Calculation
Therefore, if the depth of the cracks were doubled, the chair would have the exact same reaction to the surface....
-
4.3 Periodic Reviews.
49 CFR § 27.11(c)(2)(v) requires airports to establish a system for periodically reviewing and updating the self-evaluation required by paragraph (c)(2) of that Section. 28 CFR § 35.151...
-
DESTINATION-ORIENTED ELEVATOR
The destination-oriented elevator system then assigns an elevator car which transports the user to the selected destination floor. ...
-
218 Transportation Facilities
Section 218 provides requirements for rail stations, fixed guideway systems, bus shelters, and other transit facilities, such as airports....
-
§ 36.303(d)(2)
using the public accommodation's equipment on more than an incidental convenience basis shall make available accessible public telephones, TTYs, or other telecommunications products and systems...
-
2013 Forest Service Outdoor Recreation Accessibility Guidelines (FSORAG)
Service Outdoor Recreation Accessibility Guidelines (FSORAG) 2013 All Facilities and Features Addressed in the FSORAG that are Constructed or Altered Within the National Forest System...
-
§ 37.161(a)
These features include, but are not limited to, lifts and other means of access to vehicles, securement devices, elevators, signage and systems to facilitate communications with persons...
-
Paratransit
Part 37 uses this term to refer to the complementary paratransit service comparable to public fixed route systems which must be provided....
-
Restrictions and Priorities Based on Trip Purpose
There can be no restrictions or priorities based on trip purpose in a comparable complementary paratransit system....
-
§ 37.3 Alteration
Normal maintenance, reroofing, painting or wallpapering, asbestos removal, or changes to mechanical or electrical systems are not alterations unless they affect the usability of the building...
-
[A] APPROVED
[HCD 1, HCD 2 & DSA-AC] “Approved” means meeting the approval of the enforcing agency, except as otherwise provided by law, when used in connection with any system, material, type of...