Adult changing tables shall be fixed to the floor or a wall and shall comply with Section 11B-813.2.1....
Search Results "Floor-Level Exit Sign"
-
11B-813.2.1 Adult changing table
-
Stopping Distance
for the Development of Bicycle Facilities (pp. 40-42) uses a perception-reaction time of 2.5 seconds.(2) For this study, the perception-reaction time was measured from when the STOP sign...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
7b.
[ADA Stds 4.13.9] Yes _____ No _____ A clear floor space on the latch side of the door (pull side) allows a person using a wheelchair or scooter to pull the door open and then...
-
4.1.3(10)(a)
(a) Where only one drinking fountain is provided on a floor there shall be a drinking fountain which is accessible to individuals who use wheelchairs in accordance with 4.15 and one accessible...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-405.9.2 Curb or barrier
mm) high minimum, or barrier shall be provided that prevents the passage of a 4 inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor...
-
§ 38.23(b)(7) Platform gaps
When the platform is at vehicle floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and the vehicle floor shall not exceed...
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
-
Reasonable Modification
For example, a city sponsors college-level classes that may be used toward a college degree....
-
706.1 General
The technical standards for assistive listening systems describe minimum performance levels for volume, interference, and distortion....
-
706.1 General
The technical standards for assistive listening systems describe minimum performance levels for volume, interference, and distortion....
-
222.1 General
EXCEPTION: In alterations, where it is technically infeasible to provide rooms in accordance with 222.1, one room for each sex on each level shall comply with 803....
-
706.1 General
The technical standards for assistive listening systems describe minimum performance levels for volume, interference, and distortion....
-
R304.1 General
• Parallel curb ramps have a running slope that is in-line with the direction of sidewalk travel and lower the sidewalk to a level turning space where a turn is made to enter the pedestrian...
-
CONCLUSIONS
Increased energy expenditure would be expected on these surfaces in a wet condition for people who have increased levels of energy expenditures on less firm and stable surfaces....
-
Issue 4: Wrong pole! …Wrong message!
for the crossing on the right in Figure 7 should be installed on the pole near the right side of the photo, and on the side of the pole toward the curb ramp, but still reachable from the level...
- Murdock Manufacturing Waterless Toilet Riser with Seat and Cover
-
New Jersey Public Accommodations Poster Required by State Law
I just heard about this non-discrimination sign requirement today but it has pretty broad application. ...
-
1008.2.5.3 Handrails
Handrails shall not be required on ramps located within ground level use zones. 2. Handrail extensions shall not be required....
-
1008.2.5.3 Handrails
Handrails shall not be required on ramps located within ground level use zones. 2. Handrail extensions shall not be required....