Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element....
Search Results "Shall"
-
11B-306.2.3 Minimum required depth
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
11B-206.4.5 Tenant spaces
All entrances to each tenancy in a facility shall comply with Section 11B-404. [2010 ADA Standards] 206.4.5 Tenant Spaces....
-
11B-206.4.4.2 Direct connections
Direct connections to other facilities shall provide an accessible route complying with Section 11B-404 from the point of connection to boarding platforms and all transportation system elements...
-
11B-1005.1 Accessible routes
Accessible routes serving fishing piers and platforms, including gangways and floating piers, shall comply with Division 4....
-
11B-809.5.2.1 Activation
All visible alarm appliances provided within the residential dwelling unit for smoke detection notification shall be activated upon smoke detection....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-804.2 Clearance
Where a pass through kitchen is provided, clearances shall comply with Section 11B-804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with Section 11B-804.2.2....
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Pole-supported pedestrian traffic-control buttons shall be identified with color coding consisting of a textured horizontal yellow band 2 inches (51 mm) in width encircling the pole, and...
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture....
-
11B-232.5.1 Cubicles and counters
At least 5 percent, but no fewer than one, of cubicles shall comply with Section 11B-902 on both the visitor and detainee sides....
-
11B-1003.2.2 Boarding piers at boat launch ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in Section 11B-1003.2.2. Exceptions: 1. ...
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303. [2010 ADAS] 608.7 Thresholds. ...
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
11B-802.4.2 Identification
Each designated aisle seat shall be identified by a sign or marker with the International Symbol of Accessibility complying with Section 11B-703.7.2.1....
-
F238.2.1 Teeing Grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
11B-211.2 Minimum number
No fewer than two drinking fountains shall be provided....
-
1016.1 General
Outdoor recreation access routes shall comply with 1016. EXCEPTIONS: 1. ...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter...