(3) Wheelchair spaces and companion seats are not located on (or obstructed by) temporary platforms or other movable structures, except that when an entire seating section is placed on temporary...
Search Results "General Exception"
-
§ 36.406(f)(3)
-
608.7 Thresholds
EXCEPTION: A threshold 2 inches (51 mm) high maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (13 mm) high threshold would...
-
Multiple Single-User Toilet Rooms
rooms are clustered in a single location, fifty percent (50%), rather than the one hundred percent (100%) required by the 1991 Standards, are required to be accessible by section 213.2, Exception...
-
11B-804.2 Clearance
Exception: Spaces that do not provide a cooktop or conventional range shall not be required to comply with Section 11B-804.2. [2010 ADAS] Advisory 804.2 Clearance. ...
-
11B-233.3.1.2 Residential dwelling units with adaptable features
Exception: The number of required adaptable residential dwelling units shall be reduced by the number of units required by Section 11B-233.3.1.1....
-
703.4.1 Height above Finish Floor or Ground
[ECTCR UFAS 4.30.6] EXCEPTION: Tactile characters for elevator car controls shall not be required to comply with 703.4.1....
-
11B-306.2.3 Minimum required depth
Exceptions: 1. The toe clearance shall extend 19 inches (483 mm) minimum under sinks required to be accessible by Section 11B-212.3. 2. ...
-
11B-206.4.4.2 Direct connections
Exception: In key stations and existing intercity rail stations, existing direct connections shall not be required to comply with Section 11B-404. ...
-
231 Judicial Facilities
This section has not been changed except for a few editorial revisions: provisions specific to courtrooms have been relocated without substantive change to a new technical section...
-
11B-407.2.2.2 Visible signals
Exceptions: 1. Reserved. 2. Reserved. [2010 ADAS] 2. ...
-
M305.2.3 Height
EXCEPTION: Where the width of the transfer surface for imaging beds exceed 24 inches (610 mm), the tops of the gripping surfaces shall be permitted to be 3 inches (75 mm) minimum and 6 inches...
-
1007.8 Two-way communication
Exceptions: Two-way communication systems are not required at the elevator landing where the two-way communication system is provided within areas of refuge in accordance with Section...
-
M305.2.2.2 Side Transfer Supports
EXCEPTIONS: 1. Where transfer surfaces are part of an articulating surface, the support shall be permitted to be 15 inches (380 mm) long minimum. 2....
-
12112(b)(7)
whatever other factor of such applicant or employee that such test purports to measure, rather than reflecting the impaired sensory, manual, or speaking skills of such employee or applicant (except...
-
403.5.2 Clear Width at Turn
EXCEPTION: Where the clear width at the turn is 60 inches (1525 mm) minimum compliance with 403.5.2 shall not be required. Figure 403.5.2 Clear Width at Turn...
-
11B-231.4.1 Cubicles and counters
Exception: The detainee side of cubicles or counters at non-contact visiting areas not serving holding cells required to comply with Section 11B-231 shall not be required to comply with...
-
F247.4.4 Routes
An exception to F213.1 exempts pit toilets from the requirements for accessible toilet facilities....
-
LULA Elevator Dimensions
These dimensions permit a car at least 51 inches by 51 inches provided that the door has a clear width of at least 36 inches (408.4.1, Exception 1)....
-
502.2 Vehicle Spaces
EXCEPTION: Van parking spaces shall be permitted to be 96 inches (2440 mm) wide minimum where the access aisle is 96 inches (2440 mm) wide minimum....
-
F216.11 Check-Out Aisles
EXCEPTION: Where all check-out aisles serving a single function comply with 904.3, signs complying with 703.7.2.1 shall not be required....
-
F216.10 Assistive Listening Systems
EXCEPTION: Where ticket offices or windows are provided, signs shall not be required at each assembly area provided that signs are displayed at each ticket office or window informing patrons...
-
407.4.6.1 Location
EXCEPTIONS: 1....
-
F225.2.1 Lockers
[UFAS does not specifically refer to lockers except at 9.5 Locker Rooms under 9....
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. Figure 307.4 Vertical Clearance...