Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
Search Results "Water Closet Grab Bar"
Commonly Searched Documents
-
11B-609.2.1 Circular cross section
-
11B-609.2.1 Circular cross section
Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
11B-809.10.6.4 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum...
-
609.2.1 Circular Cross Section
Grab bars with circular cross sections shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
609.2.1 Circular Cross Section
Grab bars with circular cross sections shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
Pressalit Care VALUE Support Arm Fixed Height Swing Grab Bar with Leg
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Pressalit Care PLUS Support Arm Height and Sideways Adjustable Swing Grab Bar
Requires the Premium User plan or above. (Login or upgrade your account!)
-
609.2.1 Circular Cross Section
Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
4.26.4 Eliminating Hazards
A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
4.26.4 ELIMINATING HAZARDS
A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
Technical Memorandum TM 2013-17 Water Closet Clearance - Overlap
TM 2013-17 Water Closet Clearances - Overlap Effective Date: June 1, 2013 2012 TAS Reference: 604.3.2 Based on TAS 106.3 and the application of terms and definitions in...
-
11B-609.2.1 Circular cross section
Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
- Big John Toilet Support & Short Swivel Support informational video
- Big John Toilet Support & Short Swivel Support 7.5" to 14" Installation Video
- Big John Toilet Support & Short Swivel Support 5" to 7.5" Installation Video
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
1f
Is there a horizontal grab bar on the wall alongside the shower seat (but not behind the shower seat) for stabilization and to aid in transfer from a wheelchair to the folding shower seat...
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
Plan 6B: 12-Foot Wide Accessible Guest Room
Features include a transfer shower, water closet length (rim to rear wall) 24 inches maximum, comparable vanity, wardrobe, and door connecting to adjacent guest room....
-
Plan 6A: 12-Foot Wide Accessible Guest Room
Features include a transfer shower, water closet length (rim to rear wall) 24 inches maximum, comparable vanity, clothes closet with swinging door, and door connecting to adjacent guest...
-
Grab Bars [4.20.4] and Controls [4.20.5]
Grab Bars [4.20.4] and Controls [4.20.5] Controls must be within reach from outside the tub and cannot interfere with the use of the grab bars....