Accessible urinals shall comply with 4.18....
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
-
4.18.1 General
-
4.18.1 GENERAL
Accessible urinals shall comply with 4.18....
-
6.3(2)
(2) Each one-bed room shall have a minimum clear floor space of 36 in (915 mm) along each side of the bed, and 42 in (1065 mm) between the foot of the bed and the wall....
-
4.4.6 Surface
The surface of the clear floor or ground space for benches shall be firm and stable. The type of surface should be appropriate to the setting and level of development....
-
4.21.2 Size and Clearances
Minimum guidelines for roll-in shower stalls are based on residential size fixtures (30" x 60" minimum or the space used by a standard residential tub/shower unit) and spaces (30" minimum...
-
605 Urinals
[See subsections ...]
-
605 Urinals
[See subsections ...]
-
4.18 Urinals
[See subsections ...]
-
4.18 URINALS
[See subsections ...]
-
11B-707.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-707.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
Clear floor space beside or between beds must be 36" wide
Remember that because the clear floor space required by 806.2.3 will be deeper than 24" to end up beside or between the beds where it will be usable, it will be in an alcove that is at least...
-
Water Closet Clearances
Under the current 1991 Standards, the requisite clearance space in single-user toilet rooms between and around the toilet and the lavatory does not permit these methods of transfer....
-
Water Closet Clearances
Under the current 1991 Standards, the requisite clearance space in single-user toilet rooms between and around the toilet and the lavatory does not permit these methods of transfer....
-
11B-604.3.2 Overlap
clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear...
- Caroma® USA H2 Zero Waterless Urinal Operation Video
-
3.4.7 Openings
Openings in the clear ground space and turning space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
-
Accessible Ground Surfaces
Accessible Ground Surfaces Ground surfaces along accessible routes, clear floor or ground spaces, and maneuvering spaces, must comply with the American Society for Testing and Materials...
-
6.3(3)
(3) Each two-bed room shall have a minimum clear floor space of 42 in (1065 mm), preferably 48 in (1220 mm), between the foot of the bed and the wall; 36 in (915 mm) between the side of...
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
Knee and Toe Space [§305.4 and §306]
Knee and Toe Space [§305.4 and §306] Objects that provide space for toes or knees can overlap a portion of the clear floor space....
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH