(2) Shear stress induced in a grab bar or seat by the application of 250 lbf (1112N) shall be less than the allowable shear stress for the material of the grab bar or seat. If the...
Search Results "Outdoor Rinsing Shower"
Commonly Searched Documents
-
4.26.3(2)
-
4.26.3(3)
(3) Shear force induced in a fastener or mounting device from the application of 250 lbf (1112N) shall be less than the allowable lateral load of either the fastener or mounting...
- American Standard FloWise® Commercial Shower System Kit
-
11B-610.3.2 L-shaped seats
FIGURE 11B-610.3.2 L-SHAPED SHOWER SEAT...
-
Clear Tread Width and Passing Spaces for Outdoor Recreation Access Routes
The minimum clear tread width of an outdoor recreation access route is 36 inches (915 millimeters), which is wide enough to allow unobstructed passage by a wheelchair....
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
-
610.3.2 L-Shaped Seats
Figure 610.3.2 L-Shaped Shower Seat...
-
F244.5.1 Routes Within Camping Units with Mobility Features
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within camping units with mobility features....
-
F245.4.1 Routes Within Picnic Units with Mobility Features
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within picnic units with mobility features....
-
F244.5.1 Routes Within Camping Units with Mobility Features
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within camping units with mobility features....
-
F244.5.1 Routes within Camping Units with Mobility Features
This section requires at least one outdoor recreation access route to connect accessible elements, spaces, and facilities provided within camping units with mobility features....
-
F245.4.1 Routes within Picnic Units with Mobility Features
This section requires at least one outdoor recreation access route to connect accessible elements, spaces, and facilities provided within picnic units with mobility features....
-
Running Slope [1016.7.1]
Table 3—Maximum Running Slope and Segment Length Running Slope of Segment of Outdoor Recreation Access Route Maximum Length of Segment Steeper Than But Not...
-
F202.4 Alterations Affecting Primary Function Areas
Exception 4 is added because the final rule does not require accessible routes at camping facilities, picnic facilities, viewing areas, and trailheads where outdoor recreation access routes...
- American Specialties Folding Shower Seat 8205-L
-
610.3.2 L-Shaped Seats
[ECTCR UFAS 4.21.3, Fig. 36, 4.34.5.5(2)] Figure 610.3.2 L-Shaped Shower Seat...
-
F245.4.2.1 Routes to Common Use and Public Use Areas
At least one outdoor recreation access route shall connect each picnic unit with mobility features with common use and public use areas serving that unit....
-
Camping and Picnic Facilities [F244.2.3.1, F244.3, F245.2.5.1, and F244.5.3]
Within camping and picnic units with mobility features (figure 16), at least one of each type of outdoor constructed feature must comply with the applicable technical requirements for the...
-
1016.8 Resting Intervals
requirements for the length (1016.8.1), width (1016.8.2), and slope (1016.8.3) of resting intervals; and for a turning space (1016.8.4) where resting intervals are provided adjacent to an outdoor...
-
F245.4.2.2 Routes Within Common Use and Public Use Areas
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within common use and public use areas serving picnic units with mobility...
- Magnuson Group RETTO Outdoor Waste Receptacle
- American Specialties Folding Shower Seat 8208-R
-
1016.7.2 Cross Slope
This section requires the cross slope of outdoor recreation access routes to not be steeper than 1:48....
- Bobrick Folding Shower Seat B-5191