The Mighty has the longest reach of any of our lifts and can reach out across the pool deck by as much as 44-inches....
Search Results "Obstructed Reach"
Commonly Searched Documents
- Mighty 400 Pool & Spa Access Lift
-
Range or Cooktop: ADA Standard Section 804.6.4
The location of controls shall not require reaching across burners....
-
1015.3 Viewing Space
EXCEPTION: Guards or similar safety barriers shall be permitted to obstruct the viewing space to the extent the obstruction is necessary for the guard or safety barrier to serve its intended...
-
1015.3 Viewing Space
EXCEPTION: Guards or similar safety barriers shall be permitted to obstruct the viewing space to the extent the obstruction is necessary for the guard or safety barrier to serve its intended...
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
When doors automatically reopen due to a detected obstruction, they can begin to reclose when no longer obstructed....
-
11B-304.3.2 T-Shaped space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
11B-304.3.2 T-Shaped space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
Approach: ADA Standard Section 904.2
the sales or service counter, locate the accessible counter close to the cash register so that a person using a wheelchair is visible to sales or service personnel and to minimize the reach...
-
11B-804.6.4 Range or cooktop
The location of controls shall not require reaching across burners....
-
Back Support: ADA Standard Section 903.4
If provided, grab bars cannot obstruct transfer to the bench....
-
11B-108 Maintenance of accessible features
Inoperable elevators, locked accessible doors, or "accessible" routes that are obstructed by furniture, filing cabinets or potted plants are not accessible to nor usable by persons with...
-
4.9.4(4)
(4) Gripping surfaces shall be uninterrupted by newel posts, other construction elements, or obstructions....
-
11B-304.3.2 T-Shaped space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
4.10.6* Door Protective and Reopening Device
They shall be provided with a reopening device that will stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an object or person....
-
4.10.6* DOOR PROTECTIVE AND REOPENING DEVICE
They shall be provided with a reopening device that will stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an object or person....
- S. R. Smith Splash! Pool Lift
-
11B-226.4 Baby changing tables
Baby changing tables when deployed shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2....
-
6e.
Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach? Yes _____ No _____...
-
11B-606.1 General
If soap and towel dispensers are provided, they must be located within the reach ranges specified in Section 11B-308, except for those in toilet and bathing rooms which must comply with...
-
M307 Operable Parts
For an unobstructed forward reach or side reach, the reach ranges are 48 inches maximum for a high reach and 15 inches minimum for a low reach....
-
10 [§ 4.7.5]
A curb ramp may have returned curbs if it has non-walking surfaces (such as grass) or obstructions on both sides because these conditions would normally discourage pedestrians from walking...
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....