Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel.
Search Results "Floor Button"
Commonly Searched Documents
-
407.4.6.4.2 Location
-
407.4.6.4.2 Location
407.4.6.4.2 Location. Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel.
-
11B-407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel.
-
11B-407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel.
-
Do reach range requirements apply to elements or only to operable parts of elements?
Reach range requirements apply to the operable portions of elements, including handles, controls, switches, buttons, control pads and other mechanisms that must be activated or manipulated...
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
4.1.4 Clear Floor or Ground Space
At least 48 inches (1220 mm) of clear floor or ground space shall surround the usable sides of a picnic table, measured from the back edge of the benches....
-
1133A.2 Clear floor space
Clear floor space at kitchens shall comply with the following:...
-
811.2 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided....
-
811.2 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided....
-
4.16.2 Clear Floor Space
Clear floor space for water closets not in stalls shall comply with Fig. 28. Clear floor space may be arranged to allow either a left-handed or right-handed approach....
-
802.1.1 Floor or Ground Surface
802.1.1 Floor or Ground Surface. The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted....
-
Extended Floor or Ground Surface: ADA Standard Section 405.9.1
Section 405.9.1 covers the current ADA Standards for extended floor or ground surface of the ramp run or landing.
-
11B-406.5.4 Floor or ground surfaces
Floor or ground surfaces of curb ramps and blended transitions shall comply with Section 11B-405.4....
-
11B-406.5.4 Floor or ground surfaces
Floor or ground surfaces of curb ramps and blended transitions shall comply with Section 11B-405.4....
-
11B-406.5.4 Floor or ground surfaces
Floor or ground surfaces of curb ramps and blended transitions shall comply with Section 11B-405.4....
-
11B-608.9 Shower floor or ground surface
11B-608.9 Shower floor or ground surface. Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
810.5.3 Platform and Vehicle Floor Coordination--Modification to 810.5.3 of Appendix D to 36 CFR Part 1191
810.5.3 Platform and Vehicle Floor Coordination--Modification to 810.5.3 of Appendix D to 36 CFR Part 1191 Station platforms shall be positioned to coordinate with vehicles in accordance...
-
11B-813.2.9 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Scooter
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching to a...