Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other purpose...
Search Results "Fire Ring"
-
11B-809.5.4 Prohibited use
-
704.8 Allowable area of openings
The area of openings in an open parking structure with a fire separation distance of greater than 10 feet shall not be limited. d....
-
1.1.3.2, Item 14.5
Public school automatic fire detection, alarm, and sprinkler systems....
-
Can People with Limited Mobility Use the Usable Circulation Path by Themselves?
Elevators typically return to the ground floor when a fire alarm is activated and can be operated after that only by use of a “fire fighters” keyed switch....
-
[F] 907.4 Initiating devices
[F] 907.4.2 Manual fire alarm boxes. ......
-
704.1 General
Exterior walls shall be fire-resistance rated and have opening protection as required by this section....
-
[2010 ADAS] 105.2.4 ICC/IBC
Fire alarm systems and components shall be California State Fire Marshal approved and listed in accordance with California Code of Regulations, Title 19, Division 1. 10.3.3 All devices...
-
907.5.2.3 Visible alarms
In other than Group I-2 and I-2.1, visible alarm notification appliances are not required in alterations, except where an existing fire alarm system is upgraded or replaced, or a new fire...
-
[F] 907.5.2.3 Visible alarms
Exceptions: In other than Group I-2 and I-2.1, visible alarm notification appliances are not required in alterations, except where an existing fire alarm system is upgraded or replaced...
- Grainger Telescoping Traffic Cone Bar
-
1.1.3.2, Item 14
Applications regulated by the Office of State Fire Marshal include but are not limited to the following in accordance with Section 1.11....
-
8. Testing to Ensure Direct, Equal Access
calltaking position; whether each call was silent or transmitted tones; whether the caller received a TTY response and the content of the TTY response; the time elapsed and the number of rings...
-
704.9 Vertical separation of openings
Openings in exterior walls in adjacent stories shall be separated vertically to protect against fire spread on the exterior of the buildings where the openings are within 5 feet (1524 mm...
-
[F] 907.5.2.3 Visible alarms
In other than Group I-2 and I-2.1, visible alarm notification appliances are not required in alterations, except where an existing fire alarm system is upgraded or replaced, or a new fire...
-
4.3.11.1(4)
(4) A vestibule located immediately adjacent to an exit enclosure and constructed to the same fire-resistive standards as required for corridors and openings....
- Sioux Chief DropKick™ Offset Flange 889-45PAM
- Sioux Chief FullFlush™ Offset Flange 889-AOM
-
809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation....
-
809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation....
-
1.1.8 City, county, or city and county amendments, additions or deletions
comply with Health and Safety Code Section 18941.5 for Building Standards Law, Health and Safety Code Section 17958 for State Housing Law or Health and Safety Code Section 13869.7 for Fire...
-
1.1.2 Purpose
strength, means of egress facilities, stability, access to persons with disabilities, sanitation, adequate lighting and ventilation and energy conservation; safety to life and property from fire...
-
907.2.10 Single-and multiple-station smoke alarms
Listed single-and multiple-station smoke alarms shall be installed in accordance with the provisions of this code and the household fire-warning equipment provisions of NFPA 72....
-
711.3.4 Dissimilar materials
Noncombustible penetrating items shall not connect to combustible items beyond the point of firestopping unless it can be demonstrated that the fire-resistance integrity of the wall is maintained...