The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
Search Results "Exit Door"
Commonly Searched Documents
-
11B-404.3.5 Controls
-
4.13.5 Clear Width
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the opposite stop (see Fig. 24(a), (b), (c), and (d...
-
4.13.5 CLEAR WIDTH
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the stop (see Fig. 24(a), (b), (c), and (d))....
-
404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing....
-
404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
11B-703.5.6 Height from finish floor or ground
Floor-level exit signs complying with Chapter 10, Section 1013.7 shall not be required to comply with Section 11B-703.5.6....
-
Are exterior stairs required to comply with the Standards?
This includes exterior stairs that are part of exit discharge (i.e., the path from an exit to a public way such as a street or alley)....
-
11B-411.3.1 Type
Elevator door type shall comply with Section 11B-407.3.1....
-
4.13.12* Automatic Doors and Power-Assisted Doors
If an automatic door is used, then it shall comply with ANSI/BHMA A156.10‒1985. Slowly opening, low-powered, automatic doors shall comply with ANSI A156.19‒1984....
-
404.3 Automatic and Power-Assisted Doors and Gates
Automatic doors and automatic gates shall comply with 404.3....
-
404.3 Automatic and Power-Assisted Doors and Gates
Automatic doors and automatic gates shall comply with 404.3....
-
404.2.10 Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-408.3 Elevator doors
Elevator hoistway doors shall comply with Section 11B-408.3....
-
11B-408.3 Elevator doors
Elevator hoistway doors shall comply with Section 11B-408.3....
-
11B-408.3 Elevator doors
Elevator hoistway doors shall comply with Section 11B-408.3....
-
d. i.
Provide doors that require no more than 5 lbf to push or pull open at the following locations: (1) Spy City Café men's and women's toilet rooms; (2) Main Lobby restrooms vestibule;...
-
404.2.10 Door and Gate Surfaces
404.2.10 Door and Gate Surfaces....
-
1007.7 Signage
At exits and elevators serving a required accessible space but not providing an approved accessible means of egress, signage shall be installed indicating the location of accessible means...
-
1003.2.13.6 Signage
At exits and elevators serving a required accessible space but not providing an approved accessible means of egress, signage shall be installed indicating the location of accessible means...
-
404.2.8 Closing Speed
Door and gate closing speed shall comply with 404.2.8....
-
404.2.8 Closing Speed
Door and gate closing speed shall comply with 404.2.8....
-
4.13.11(2)(b)
(b) interior hinged doors: 5 lbf (22.2N)...