Button spacing shall comply with Section 11B-407.4.7.1.5.
Search Results "Elevator Landing"
Commonly Searched Documents
- 
    
  
  11B-411.4.7.4 Button spacing
  
- 
    
  
  11B-407.2.2 Hall signals
  Hall signals, including in-car signals, shall comply with Section 11B-407.2.2. 
- 
    
  
  11B-407.4.6.2.4 Operation
  Car control buttons shall be activated by a mechanical motion that is detectable. 
- 
    
  
  11B-407.4.10.3 Structural strength
  Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting... 
- 
    
  
  11B-407.4.10.1 Location
  Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum. Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above... 
- 
    
  
  11B-407.4.10.2 Surfaces
  Support rails shall be smooth and any surface adjacent to them shall be free of sharp or abrasive elements. 
- 
    
  
  11B-407.4.7.1 Buttons
  Car control buttons shall comply with Section 11B-407.4.7.1. 
- 
    
  
  11B-407.4.6.2.2 Arrangement
  Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right. 
- 
    
  
  11B-411.4.6.1 Location
  Controls shall be located within one of the reach ranges specified in Section 11B-308. 
- 
    
  
  11B-407.4.6.2.1 Size and shape
  11B-407.4.6.2.1 Size and shape. Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch... 
- 
    
  
  11B-411.2.3.2 Car designation signs
  Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation. Signs shall be... 
- 
    
  
  11B-411.4.7.1 Type
  Control button type shall comply with Section 11B-407.4.7.1.1. 
- 
    
  
  1009.4.1 Standby power
  The elevator shall meet the emergency operation and signaling device requirements of California Code of Regulations, Title 8, Division 1, Chapter 4, Subchapter 6, Elevator Safety Orders.... 
- 
    
  
  11B-407.4.7.1.3 Symbols
  TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION Control Button Tactile Symbol Braille Message Emergency Stop... 
- 
    
  
  407.4.7 Designations and Indicators of Car Controls
  EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.7 is provided, existing car operating panels shall not be required to comply with 407.4.7.... 
- 
    
  
  11B-407.4.7 Designations and indicators of car controls
  Exception: In existing elevators, where a new car operating panel complying with Section 11B-407.4.7 is provided, existing car operating panels may remain operational and shall not be required... 
- 
    
  
  11B-407.4.7 Designations and indicators of car controls
  Exception: In existing elevators, where a new car operating panel complying with Section 11B-407.4.7 is provided, existing car operating panels may remain operational and shall not be required... 
- 
    
  
  11B-407.4.7 Designations and indicators of car controls
  Exception: In existing elevators, where a new car operating panel complying with Section 11B-407.4.7 is provided, existing car operating panels may remain operational and shall not be required... 
- 
    
  
  405.9.1 Extended Floor or Ground Surface
  The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505.... 
- 
    
  
  216.7 Elevators
  216.7 Elevators.... 
- 
    
  
  Connected Elevated Components
  Connected Elevated Components When transfer systems are used, an elevated play component may connect to other elevated play components, providing an innovative, accessible route.... 
- 
    
  
  Automatic Operation [4.10.2]
  The elevator must be automatically operable by the passenger.... 
- 
    
  
  11B-407.4.7.1.4 Visible indicators
  Buttons with floor designations shall be provided with visible indicators to show that a call has been registered. The visible indication shall extinguish when the car arrives at the... 
- 
    
  
  11B-411.2.1.4.1.1 Arrangement
  Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same... 