clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear...
Search Results "Clear Floor Space"
Commonly Searched Documents
-
11B-604 Water closets and toilet compartments
- Landscape Forms Inc. Wellspring Trash Receptacle
-
H13
Is the operating control (switch, lever, button, or pull) of at least one of each type of dispenser or built-in equipment no higher than 54 inches above the floor (if there is clear floor...
-
Size and Clearances [4.21.2]
Size and Clearances [4.21.2] Lavatories can be located within the clear floor space (as shown in ADAAG Figure 35)....
-
Clear Width: ADA Standard Section 404.3.1
Section 404.3.1 covers the current ADA Standards for clear width at automatic and power-assisted doors and gates.
-
Floor or Ground Surface: ADA Standard Section 403.2
Section 403.2 covers the current ADA Standards for floor or ground surfaces that are part of an accessible route.
-
Exercise Machines and Equipment
Section 236 of the 2010 Standards requires at least one of each type of exercise machine to meet clear floor space requirements of section 1004.1....
- Magnuson Group BALLOON Outdoor Waste Receptacle
- Landscape Forms Inc. Petoskey Trash Receptacle
-
1134A.6, Item 3
Floor space. ...
-
1134A.6, Item 3
Floor space....
-
Floor or Ground Surface: ADA Standard Section 1002.4.1
The floor or ground surface of wheelchair spaces shall be stable and firm....
- Landscape Forms Inc. Chase Park Trash Receptacle
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element....
-
Size and Clearances [4.21.2]
Size and Clearances [4.21.2] Clear floor space is specified for side transfers. Where a forward approach is provided, space at least 60 inches wide provides room for turning....
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element. Exceptions: 1. ...
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element....
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard, such as 404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2...
-
4.5.2.1 Forward Approach
The clear floor or ground space for a forward approach shall be 36 inches (915 mm) by 48 inches (1220 mm)....
-
4.5.2.2 Side Approach
The clear floor or ground space for a side approach shall be 30 inches (760 mm) by 60 inches (1525 mm)....
-
I1a
For a side approach (clear floor space at least 30 inches long x 48 inches wide), is the coin slot no higher than 54 inches above the floor?...
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....