Recommendations also noted that unisex facilities are also referred to as "single use" or "family" toilet and bathing rooms in some codes. Response....
Search Results "Existing Facility"
-
Unisex Toilet Rooms
-
Technical Memorandum TM 2013-22 Storage (Kitchens and Kitchenettes)
TM 2013-22 Storage (Kitchens and Kitchenettes) Effective Date: October 3, 2013 2012 TAS Reference: 804.5 TAS 804.5 requires at least 50% of the shelf space in storage facilities...
-
Accessible Swimming Pools and Spas
Freedom Initiative, February 1, 2001 The guidelines described in this guide focus on newly designed or newly constructed and altered swimming pools, wading pools, aquatic recreation facilities...
-
Showers
The final Guidelines for usable bathrooms (the first set of specifications) specify size dimensions for shower stalls in only one situation -- when the shower stall is the only bathing facility...
-
608.6 Shower Spray Unit and Water
EXCEPTION: A fixed shower head located at 48 inches (1220 mm) maximum above the shower finish floor shall be permitted instead of a hand-held spray unit in facilities that are not medical...
-
608.6 Shower Spray Unit and Water
EXCEPTION: A fixed shower head located at 48 inches (1220 mm) maximum above the shower finish floor shall be permitted instead of a hand-held spray unit in facilities that are not medical...
-
Application [§201]
Application [§201] The ADA Standards apply to the various types of facilities subject to the ADA, from simple structures to complex, multi-building sites such as university campuses and...
-
E202.6.1 Required Documentation (Section-by-Section Analysis)
Documenting the exception for commercial non-availability is not a requirement in the existing 508 Standards, though such documentation is mandated under the current federal acquisition...
-
Peripheral Devices (Section-by-Section Analysis)
that when it is not readily achievable to make telecommunications equipment or customer premises equipment accessible, manufacturers shall ensure that the equipment is compatible with existing...
-
4.2 Overview of Legal Obligations
An employer is not required to lower existing production standards applicable to the quality or quantity of work for a given job in considering qualifications of an individual with a disability...
-
V. Modifications in Policies, Practices, and Procedures
Modifications in existing practices generally must be made to permit the use of guide dogs and other service animals....
-
11B-211.2 Minimum number
The 2013 California Plumbing Code (CPC), Table 4-1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
11B-404.2.11 Vision lights
An existing door with a noncompliant vision light is a Safe Harbored element for path of travel and barrier removal purposes, but will have to comply when the door is replaced, and may not...
-
407.2.2.3 Audible Signals
Existing elevators shall not be required to comply with the requirements for frequency and dB range of audible signals....
-
407.2.2.3 Audible Signals
Existing elevators shall not be required to comply with the requirements for frequency and dB range of audible signals....
-
General (R304.1) (Section-by-Section Analysis)
In alterations where existing physical constraints make it impractical to fully comply with the technical requirements, compliance is required to the extent practicable within the scope...
-
A. Entrances
Francis Street Exterior Route to Existing Parking Deck, Pool, Fitness Center, and Spa – Defendants will provide an accessible route from the parking deck to the pool, fitness center, and...
-
A. Complaint Procedures and Complaints Resolution Officials (CRO’s)
carrier must make a CRO available to any person who makes a disability-related complaint during all times the carrier is operating at an airport and should make that person aware of the existence...
-
407.2.2.3 Audible Signals
Existing elevators shall not be required to comply with the requirements for frequency and dB range of audible signals....
-
407.12.2 Side Reach (Section-by-Section Analysis)
Although the existing 508 Standards do not include a maximum height for the portion of the ICT over which a person must reach, the proposed 34 inches maximum height is consistent with ICC...
-
Question 16
Are there existing standards that the Department should look to for developing standards for beds in accessible rooms?...
-
Floor Plan of Elevator Cars [4.10.9]
In alterations, smaller car sizes (minimum 47 inch width and 69 inch length) are permitted in cases of technical infeasibility, including where limited by existing shaft configurations (...