Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
Search Results "State Requirement"
-
11B-404.2.8.1 Door closers and gate closers
-
11B-208.2.4 Van parking spaces
For every six or fraction of six parking spaces required by Section 11B-208.2 to comply with Section 11B-502, at least one shall be a van parking space complying with Section 11B-502....
-
11B-1009.3.1 Sloped entries
Exception: Where sloped entries are provided, the surfaces shall not be required to be slip resistant....
-
11B-1009.3.1 Sloped entries
Exception: Where sloped entries are provided, the surfaces shall not be required to be slip resistant....
-
11B-1008.3.2 Transfer steps
Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required to be on accessible routes....
- Inpro Corporation ENDURANT® Ceiling Hung Partitions
- AquaTrek2 ADA Transfer System
- PDQ MR Series Mortise Lock
- TownSteel CSRC Series, Grade 2, Clutched, Conical Rose Cylindrical Locks
- Safety Step TD Parking Stall Mats
- Bobrick Koala Kare Horizontal, Wall-Mounted Baby Changing Station KB200
- Inpro Corporation ENDURANT® Floor-Mounted Overhead-Braced Partitions
- TownSteel CB Series, Grade 2 Non-Clutched Flat Rose Cylindrical Locks
- Norton Surface Mounted Heavy Duty 9500 Series Door Closer
- TownSteel ED5500 Grade 1 Panic Rim Device
-
11B-604.8.1.5 Grab bars
Where separate grab bars are required on adjacent walls at a common mounting height, an L-shaped grab bar meeting the dimensional requirements of Sections 11B-604.5.1 and 11B-604.5.2 shall...
-
Guest Rooms with Communication Features: ADA Standard Section 806.3
Guest rooms required to provide communication features shall comply with 806.3. Advisory 806.3 Guest Rooms with Communication Features....
-
11B-209.2.1 Passenger drop-off and loading zones
Passenger drop-off and loading zones, except those required to comply with Sections 11B-209.2.2 and 11B-209.2.3, shall provide at least one passenger drop-off and loading zone complying...
-
Door and Gate Opening Force: ADA Standard Section 404.2.9
Section 404.2.9 covers the current ADA Standards for door and gate opening force.
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
11B-209.2.1 Passenger drop-off and loading zones
Passenger drop-off and loading zones, except those required to comply with Sections 11B-209.2.2 and 11B-209.2.3, shall provide at least one passenger drop-off and loading zone complying...
-
11B-211.2 Minimum number
The 2022 California Plumbing Code (CPC), Table 4-1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
11B-604.8.1.5 Grab bars
Where separate grab bars are required on adjacent walls at a common mounting height, an L-shaped grab bar meeting the dimensional requirements of Sections 11B-604.5.1 and 11B-604.5.2 shall...
-
11B-211.2 Minimum number
The 2022 California Plumbing Code (CPC), Table 4-1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...