Exterior ramps must be designed so that water does not accumulate on the ramp or landing surface. A slope up to 2% is allowed at landings for adequate drainage....
Search Results "Door Surface"
-
Outdoor Conditions [4.8.8]
-
APPENDIX C
What was your pain/discomfort value associated with this surface (circle)?...
-
1011.4 Picnic Tables
This section requires picnic tables to comply with the technical requirements for dining surfaces in 902.3 of the Architectural Barriers Act Accessibility Guidelines, which requires the...
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
1133A.4 Countertops
A minimum linear length of 30 inches (762 mm) of countertop shall be provided for a work surface. ...
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches (1524...
-
Transfer Supports Location and Configuration M301.3 and M302.3
Transfer Supports Location and Configuration M301.3 and M302.3 Location of the transfer supports shall be a minimum of 6 inches to a maximum of 19 inches from the top of the transfer surface...
-
STORY
[DSA-AC] That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above....
-
§382.125(c)
(c) You must provide for the checking and timely return of passengers' wheelchairs, other mobility aids, and other assistive devices as close as possible to the door of the aircraft, so...
-
D5
If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides?...
-
M5
If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides?...
-
5e.
Are signs mounted on both sides of the elevator hoistway door opening that designate the floor with 2-inch minimum-height raised letters and Braille characters centered at 60 inches above...
-
Hardware [4.25.4]
Hardware [4.25.4] Hardware should be exposed (as required for sliding doors in 4.13) and must: be automatic or operable with one hand operate without tight grasping,...
-
III-7.5190 Dressing and fitting rooms
Technical standards are provided for doors, benches, and mirrors, with less stringent standards for alterations....
-
609 Grab Bars
Specifications address size, spacing, position, surfaces, fittings, and structural strength....
-
Floor Height [1013.4]
If the tent platform floor is raised above grade, the floor height must be no more than 19 inches when measured from the clear ground space to the tent platform surface....
-
2.7 Tread Obstacles
Where tread obstacles exist on the surface of an ORAR, they shall not exceed 1 inch (25 mm) in height....
-
Literature Cited
Standard test method for shock-absorbing properties of playing surface systems and materials. ASTM F355-95, Vol. 15.07....
-
Story
That portion of a building included between the upper surface of a floor and upper surface of the floor or roof next above....
-
Subject testing
A study was designed to investigate a correlation between surface roughness and WBV exposure to WC users in an attempt to determine which surfaces should be considered acceptable....
-
Feature 3 - Building Entrance
An accessible entrance must provide at least one accessible door with maneuvering space, accessible door hardware, and enough clear width to allow people who use crutches, canes, walkers...
-
Policies and Procedures
A store that has a special accessible entrance that remains locked during business hours will need to change the policy and keep the door unlocked when the store is open....
-
Who Will Provide the Assistance?
Anyone in the Office or Building People with limited mobility who are able to go up and down stairs easily but have trouble operating door locks, latches, and other devices due to limitations...
-
How to Use this Checklist
Gather Tools Checklist Clipboard makes it easier to write on the checklist Tape measure Electronic or carpenter’s level - 24 inches Door pressure...