If the tent platform floor is raised above grade, the floor height must be no more than 19 inches when measured from the clear ground space to the tent platform surface....
Search Results "Parking Space"
Commonly Searched Documents
-
Floor Height [1013.4]
-
§8.32(b)
(b) For purposes of this section, section 4.1.6(1)(g) of UFAS shall be interpreted to exempt from the requirements of UFAS only mechanical rooms and other spaces that, because of their intended...
-
§104.23(c)(2)
(2) For purposes of this section, section 4.1.6(1)(g) of UFAS shall be interpreted to exempt from the requirements of UFAS only mechanical rooms and other spaces that, because of their intended...
-
407.4.7.1.2 Location
EXCEPTION: Where space on an existing car operating panel precludes tactile markings to the left of the controls, markings shall be placed as near to the control as possible....
-
Locker Rooms
Turning space at the bench, although not required, will allow easier wheelchair maneuvering to and from the bench....
-
2.9.1 Natural Elements
However, safety regulations or Forest Service construction and maintenance standards may define clear space and limit the allowable extension of natural protruding objects over the ORAR...
-
1013.3 Slope
This section requires the slope of the surface of tent pads, tent platforms, and clear ground spaces to not be steeper than 1:48 in any direction....
-
1133A.2, Item 2
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other fixtures or appliances...
-
105.2.2 ASME
Copies of the referenced standards may be obtained from the American Society of Mechanical Engineers, Three Park Avenue, New York, New York 10016 (http://www.asme.org)....
-
105.2.2 ASME
Copies of the referenced standards may be obtained from the American Society of Mechanical Engineers, Three Park Avenue, New York, New York 10016 (http://www.asme.org)....
-
Introduction
The Access Board is also developing guides for toilet and bathing facilities, parking facilities, and other elements and spaces that are required to be accessible by the ABA Standards. ...
-
Physical Accessibility
including parents, are not denied access to the school’s programs or activities because of inaccessible facilities, including academic buildings, walkways, restrooms, athletic facilities, and parking...
- Alertus Desktop Notification
- Project LETS (Let's Erase the Stigma)
-
11B-404.2.9 Door and gate opening force
force at non-rated exterior doors is more stringent than the 2010 ADA Standards, and can be difficult to meet without a powered device at exterior doors exposed to wind, or leading from spaces...
-
1.1.3.2 State-regulated buildings, structures, and applications
Permanent buildings and permanent accessory buildings or structures constructed within mobile-home parks and special occupancy parks regulated by the Department of Housing and Community...
-
Exception for accessible means of egress in existing buildings in IBC 2000
Accessible spaces shall be provided with not less than one accessible means of egress....
-
Applying the Accessibility Standards to the Plan, Installation, and Maintenance of Ground Level Accessible Routes for Playgrounds
Is the surface for the accessible route, clear ground space and turning space compliant with ASTM F1951-99 Standard Specification for Determination of Accessibility of Surface Systems Under...
-
Transfer Surface Size: Equipment Used by Patients in a Seated Position (M302.2.2)
The space available for transfer on diagnostic equipment used by patients in a seated position is smaller than the space available on diagnostic equipment used by patients in a supine, prone...
-
11B-407.4.7.1.2 Location
[2010 ADAS] EXCEPTION: Where space on an existing car operating panel precludes tactile markings to the left of the controls, markings shall be placed as near to the control as possible...
-
806.2 Guest Rooms with Mobility Features
The requirements in Section 806.2 do not include requirements that are common to all accessible spaces....
-
209.2.1 Passenger Loading Zones
except those required to comply with 209.2.2 and 209.2.3, shall provide at least one passenger loading zone complying with 503 in every continuous 100 linear feet (30 m) of loading zone space...
-
R215 Passenger Loading Zones
loading zones other than transit stops are provided, at least one accessible passenger loading zone complying with R310 shall be provided for each 30 m (100.0 ft) of continuous loading zone space...