shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor...
Search Results "Centered Clear Floor Space"
-
604.8.1.1 Size
-
604.8.1.1 Size
shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor...
-
604.8.1.1 Size
shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor...
-
1.17 Unobstructed view
is not blocked or interfered with by any seats, railings, or other objects and is configured to have visual clearance over average height patrons seated one row ahead of the wheelchair spaces...
-
1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
7.4.9 Trail Facilities
When the surface of the required clear ground space for trail facilities is not paved or is not elevated above the natural ground, slopes not steeper than 1:20 (5 percent) shall be permitted...
- Whitehall Mfg. Single Temp Hemispherical Widespread Pushbutton Pneumatic Valve Conical Faucet
-
306.2.4 Additional Clearance
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
-
M301.2.1, M302.2.1 Transfer Height
Stretchers are also widely used in outpatient surgery centers. Other considerations for stretchers are the surfaces (mattress) that is purchased separate from the stretcher deck....
-
3.13(c) Companion Seating
Companion Seating At least one fixed companion seat shall be provided adjacent to each wheelchair space....
-
502.6 Identification
Parking space identification signs shall include the International Symbol of Accessibility complying with 703.7.2.1....
-
11B-605.5.3 Doors
Exception: When located at the side wall or partition of a urinal compartment, the compartment door opening shall provide a clear width of 34 inches (864 mm) minimum....
-
11B-605.5.3 Doors
Exception: When located at the side wall or partition of a urinal compartment, the compartment door opening shall provide a clear width of 34 inches (864 mm) minimum. ...
-
F206.2.3 Multi-Story Buildings and Facilities
Spaces and elements located on a level not required to be served by an accessible route must fully comply with this document....
-
11B-705.2 Detectable directional texture
The raised bars shall be 1.3 inches (33 mm) wide and 3 inches (76 mm) from center-to-center of each bar....
-
11B-705.2 Detectable directional texture
The raised bars shall be 1.3 inches (33 mm) wide and 3 inches (76 mm) from center-to-center of each bar....
-
Transfer Platform: ADA Standard Section 1009.5.1
Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
4.4 Knee and Toe Clearances
It is clear that those people who need the largest knee and toe clearances cannot be accommodated without making some radical changes to the design of counters, drinking fountains and other...
-
3. MAP YOUR COMMUNITY
that may serve as resources during an emergency: Social service organizations, faith-based organizations Active coalitions, civic or tenant associations Public spaces...
- Spectrum Aquatics Glacier Platform Pool Lift
- Lutron Sivoia QS Wireless Shading System
-
Appendix Three: Bibliography
Space Requirements for Wheeled Mobility Devices in Public Transportation: Analysis of Clear Floor Space Requirements....