Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with 708.4....
Search Results "Floor Surface"
-
708.4 Residential Dwelling Unit Communication Systems
-
11B-809.10.2 Number of complying bathrooms and fixtures
Within dormitories in housing at a place of education, dormitory floors served by an accessible route and providing only sleeping rooms complying with 11B-809.6, and where bathrooms are...
-
11B-608.6 Shower spray unit and water
One shower head shall be located at a height of 48 inches (1219 mm) maximum above the shower finish floor....
-
11B-703.5.5 Character height
Exception: Where provided, floor plans providing emergency procedures information in accordance with Title 19 shall not be required to comply with Section 11B-703.5.5....
-
11B-703.5.5 Character height
Exception: Where provided, floor plans providing emergency procedures information in accordance with Title 19 shall not be required to comply with Section 11B-703.5.5....
-
11B-608.6 Shower spray unit and water
One shower head shall be located at a height of 48 inches (1219 mm) maximum above the shower finish floor....
-
11B-809.10.2 Number of complying bathing rooms and fixtures
Within dormitories in housing at a place of education, dormitory floors served by an accessible route and providing only sleeping rooms complying with 11B-809.6, and where bathrooms are...
-
Serving Counters
Serving Counters Where food or drinks are served at counters and the counter height is more than 34 inches above the floor, providing a lowered section of the serving counter at least...
-
403.5 Clearances
Walking surfaces shall provide clearances complying with 403.5....
-
1017.10 Trailhead Signs
Surface type; 3. Typical and minimum tread width; 4. Typical and maximum running slope; and 5. Typical and maximum cross slope....
-
R402.2 Protrusion Limits
Objects with leading edges more than 685 mm (2.25 ft) and not more than 2m (6.7 ft) above the finish surface shall protrude 100 mm (4 in) maximum horizontally into pedestrian circulation...
-
505.10.1 Top and Bottom Extension at Ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....
-
APPENDIX D
APPENDIX D National Center on Accessibility- Playground Surface Study Rotational Penetrometer Data Form ETA Editor's Note Click here to download the pdf version of the...
-
1017.10 Trailhead Signs
Surface type; 3. Typical and minimum tread width; 4. Typical and maximum running slope; and 5. Typical and maximum cross slope....
-
11B-505.10.1 Top and bottom extension at ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....
-
11B-1009.2.2 Seat location
The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48....
-
CURB RAMP
A sloping pedestrian way, intended for pedestrian traffic, which provides access between a walk or sidewalk and a surface located above or below an adjacent curb face....
-
11B-1009.2.2 Seat location
The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48....
-
11B-505.10.1 Top and bottom extension at ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run. ...
-
505.10.1 Top and Bottom Extension at Ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....
-
403.5 Clearances
Walking surfaces shall provide clearances complying with 403.5....
-
1009.2.2 Seat Location
The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48....
-
EXHIBIT F ADA Maintenance Checklist
The floor must be smooth and level. a. Is there sufficient clear floor space in front of all items on self-service shelves and dispensing devices? ___ Yes ___ No b....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....