The transfer surface should be located such that the long dimension of 28 inches is located parallel to the patient scanning/imaging side of the table....
Search Results "Side Entry"
Commonly Searched Documents
-
5.2.1.4 Transfer Surface Size for Imaging Equipment
-
Minimum Clear Opening
These commenters supported Option Two's approach, which provided for clear width to be determined by the clear floor space available for maneuvering on both sides of the door, with the minimum...
-
5.4.1 Transfer Support Location for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.1 Transfer Support Location for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
M301.2.2 Transfer Surface Size
When the transfer surface is located as described above in “A”, the width of the patient scanning/imaging table (side to side) at the designated transfer location should be 28 inches minimum...
-
Positioning Supports Considered
The Board is considering requiring in the final standards positioning supports such as rails, bars, or panels with handholds to be provided along the sides of diagnostic equipment used by...
-
Swimming Pools, Wading Pools & Spas
Word Fillable Form (2.8MB) Word Non-Fillable Form (2.6MB) PDF Non-Fillable Form (1.0MB)
- Accessible Pittsburgh: The One Step Project
- Retail Store Disability Access; Dawn Secret Treasures: BigBell
- AXS Map - How to Search and Review a Place
-
4.3 Reach Ranges
Upper Side Reach Figure 19....
-
Clearances Around Gripping Surfaces
is considering whether 1½ inches minimum clearance around the gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying...
-
5.4.1.2 Transfer and Positioning Support Location for Imaging Equipment
The transfer supports or positioning supports should be located opposite the transfer side....
-
M301.3.3 Head and Back Support
M301.3.3 Head and Back Support Proposed requirement: Where diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients...
-
Stirrups (M301.3.2)
Where stirrups are provided on diagnostic equipment used by patients in a supine, prone, or side-lying position, M301.3.2 would require the stirrups to provide a method of supporting, positioning...
-
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
Supports (M301.3, M302.3, and M305.2)
M301.3, M302.3, and M305.2 provide technical criteria for transfer and positioning supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic...
- Detecto BRW1000 Portable Wheelchair Scale
- seca 676 r Digital Wheelchair Scale with Handrail and Integrated RS232 Interface
- seca 684 r Digital Multifunctional Scale with Integrated RS232 Interface
-
5.6.1 Stirrups Provision for M301
5.6.1 Stirrups Provision for M301 NPRM Description: For patients with limited leg strength and control, thigh, knee and calf supports are necessary to maintain an appropriate...
-
4.27.3* Height
The highest operable part of controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....