Parking spaces provided to serve residential facilities shall comply with 208.2.3....
Search Results "Private Facility"
-
208.2.3 Residential Facilities
-
Door Swing: ADA Standard Section 603.2.3
Section 603.2.3 covers the current ADA Standards for door swings at clear floor space and clearances at fixtures in toilet and bathing rooms.
-
§104.33(c)(4) Placement of handicapped persons by parents
conformance with the requirements of this section and §104.34, a free appropriate public education to a handicapped person and the person's parents or guardian choose to place the person in a private...
-
11B-206.4.8 Service entrances
If a service entrance is the only entrance to a building or to a tenancy in a facility, that entrance shall comply with Section 11B-404....
-
11B-206.4.8 Service entrances
If a service entrance is the only entrance to a building or to a tenancy in a facility, that entrance shall comply with Section 11B-404....
-
F206.4.4 Transportation Facilities
In addition to the requirements of F206.4.2, F206.4.3, and F206.4.5 through F206.4.9, transportation facilities shall provide entrances in accordance with F206.4.4....
-
206.4.4 Transportation Facilities
In addition to the requirements of 206.4.2, 206.4.3, and 206.4.5 through 206.4.9, transportation facilities shall provide entrances in accordance with 206.4.4....
-
Temporary Facilities
Temporary Facilities ADAAG also requires temporary facilities such as bleachers for tournaments, assembly seating areas, portable toilet facilities, concessions, and all other available...
-
223 Medical Care and Long-Term Care Facilities
The general scoping provision at 223.1 indicates that the facilities covered by this section include medical care facilities and licensed long-term care facilities where the period of stay...
-
Historic Facilities (Preamble, Section-by-Section Analysis)
- As mandated by the ADA, the Board has established a procedure to be followed with respect to alterations to historic facilities....
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
409.4.6 Car Controls
Elevator car control buttons shall comply with 409.4.6, 309.3, 309.4, and shall be raised or flush.
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1.
-
409.4.1 Inside Dimensions of Elevator Cars
Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305.
-
11B-409.4.6 Car controls
Elevator car control buttons shall comply with Sections 11B-409.4.6, 11B-309.3, 11B-309.4, and shall be raised or flush.
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305.
-
409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (13 mm) under rated loading to zero loading conditions.
-
409.4.6.1 Size
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1.
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension.
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1.