Door openings shall provide a clear width of 32 inches (813 mm) minimum....
Search Results "Power Assisted Door"
Commonly Searched Documents
-
11B-404.2.3 Clear width
-
404.2.3 Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....
-
404.2.3 Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
-
16. Opening Building Doors
For paratransit services, a passenger's request for the driver to open an exterior entry door to a building to provide boarding and/or alighting assistance to a passenger with a disability...
-
4.13.11* Door Opening Force
The maximum force for pushing or pulling open a door shall be as follows:...
-
408.3.2.1 Power Operation
408.3.2.1 Power Operation....
-
General: ADA Standard Section 219.1
Section 219.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for assistive listening systems.
-
1009.7.1 Size
Each exterior area for assisted rescue shall be sized to accommodate wheelchair spaces in accordance with Section 1009.6.3....
-
Development of Technical Assistance Manual
Development of Technical Assistance Manual In 2000, Congress required DOT to create a technical assistance manual to provide guidance to individuals and entities with rights or responsibilities...
-
§ 36.311 Mobility devices.
[See subsections ...]
-
404.2.1 Revolving Doors, Gates, and Turnstiles
404.2.1 Revolving Doors, Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
Can the carrier limit the amount of money they pay me for this claim...as they currently may for domestic baggage claims?
QUESTION: I was flying a U.S. carrier from New York to California and they damaged my expensive battery-powered wheelchair. I purchased this wheelchair last year for $10,000....
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
Assessment Factors
All types of devices powered by fuel or combustion engines, for example, may be excluded from indoor settings for health or environmental reasons, but may be deemed acceptable in some outdoor...
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
2.2.6 Door Use
2.2.6 Door Use Our study of door use had three main objectives all intended to provide groundwork for future studies aimed at design guidelines and standards that would make doors more...
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
-
Door and Gate Surfaces [§404.2.10]
Door and Gate Surfaces [§404.2.10] The bottom surface of doors and gates on the push side must be smooth to a height of at least 10”....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
The stadium must provide receivers for the assistive listening system.
• The stadium must provide receivers for the assistive listening system. The number of available receivers must equal four percent of the total number of seats....
-
Door and Gate Hardware [§404.2.7]
Door and Gate Hardware [§404.2.7] Door and gate hardware must: allow one-hand operation not require tight grasping, pinching, or twisting of the wrist operate...