The type of surface material selected and play area use levels will determine the frequency of inspection and maintenance activities....
Search Results "Play Area Ramp"
-
Ground Surfaces: ADA Standard Section 1008.2.6
-
240.2.2 Elevated Play Components
Advisory 240.2.2 Elevated Play Components. A double or triple slide that is part of a composite play structure is one elevated play component....
-
Ramp
Ramp - A walking surface that has a running slope of greater than 1:20....
-
GameTime Adaptive Swing Seat
Requires the Premium User plan or above. (Login or upgrade your account!)
-
F240.2.2 Elevated Play Components
A double or triple slide that is part of a composite play structure is one elevated play component....
-
240.2.2 Elevated Play Components
A double or triple slide that is part of a composite play structure is one elevated play component....
- Figure 405.7 Ramp Landings – Drawing from the U.S. Access Board
-
Area of Sport Activity
That portion of a room or space where the play or practice of a sport occurs....
-
Maneuvering Space Where Ramps are Provided
Maneuvering Space Where Ramps are Provided At least one maneuvering space must be provided on the same level as the play component....
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings at perpendicular curb ramps shall extend 36 inches (914 mm) in the direction of travel....
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings at perpendicular curb ramps shall extend 36 inches (914 mm) in the direction of travel....
-
AREA OF SPORT ACTIVITY
That portion of an indoor or outdoor space where the play or practice of a sport occurs....
-
AREA OF SPORT ACTIVITY
That portion of an indoor or outdoor space where the play or practice of a sport occurs....
-
Error/Omission: Landing areas where ramps change direction (e.g., switchbacks or 90° turns) are too small.
Error/Omission: Landing areas where ramps change direction (e.g., switchbacks or 90° turns) are too small....
-
Start of Play Areas
Start of Play Areas The clear floor or ground space area at the start of play for each accessible hole must be 48 by 60 inches minimum to allow players to position themselves for the...
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
Handrail Extensions: ADA Standard Section 505.10
Section 505.10 covers the current ADA Standards for handrail extensions.
-
Assembly Area
For the purposes of these requirements, assembly areas include, but are not limited to, classrooms, lecture halls, courtrooms, public meeting rooms, public hearing rooms, legislative chambers...
-
11B-406.3.1 Slope
The running slope of the curb ramp segments shall be in-line with the direction of sidewalk travel. Ramp runs shall have a running slope not steeper than 1:12....
-
11B-406.3.1 Slope
The running slope of the curb ramp segments shall be in-line with the direction of sidewalk travel. Ramp runs shall have a running slope not steeper than 1:12....
-
Performance Areas: ADA Standard Section 206.2.6
Section 206.2.6 covers scoping requirements in the most current ADA Standards for accessible routes in performance areas.
-
Soft Contained Play Structures
Soft Contained Play Structures "Soft contained play equipment" is a play structure made of one or more components, on which an individual enters a fully enclosed play environment that...
-
106.5.27 Elevated Play Component
A play component that is approached above or below grade and that is part of a composite play structure consisting of two or more play components attached or functionally linked to create...