: A transfer type shower compartment 36 inches (914 mm) wide by 36 inches (914 mm) deep, clear inside dimensions measured at center points of opposing sides, with an entrance opening...
Search Results "Opening"
-
11B-809.10.6.1 Size
-
C.6.v. - Is the requirement to open or close caption, and to provide audio description specific to English?
No. The requirement to caption (i.e., to provide access to audio information for persons with hearing impairments) and provide audio description applies irrespective of the language....
-
Attachment H: Modifications to Altered Facilities
Attachment H: Modifications to Altered Facilities
-
Duration: ADA Standard Section 408.3.2.2
Section 408.3.2.2 covers the current ADA Standards for the duration of swinging doors on limited-use/limited-application elevator.
-
Door Delay: ADA Standard Section 407.3.5
Section 407.3.5 covers the current ADA Standards for elevator door delay.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
Swinging Doors: ADA Standard Section 408.3.2
Section 408.3.1 covers the current ADA Standards for limited-use/limited-application elevator swinging doors.
-
Symbols: ADA Standard Section 407.4.7.1.3
Section 407.4.7.1.3 covers the current ADA Standards for the designation and indicator symbols on elevator car control buttons.
-
11B-1002.4.5 Ride entry
Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (813 mm) minimum clear....
-
11B-1002.4.5 Ride entry
Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (813 mm) minimum clear....
-
Ride Entry: ADA Standard Section 1002.4.5
Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (815 mm) minimum clear....
-
1009.4.2 Area of refuge
Exceptions: Areas of refuge are not required at the elevator in open parking garages....
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
Faucets: ADA Standard Section 606.4
Section 606.4 covers the current ADA Standards for the faucet controls of lavatories and sinks.
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....
-
EXHIBIT A Required Accessible Elements at QuikTrip Stores
QuikTrip Stores Open as of the Effective Date. The following provisions apply to QuikTrip Stores that are open for business as of the Effective Date of the Consent Decree. ...
-
11B-606.4 Faucets
Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
11B-606.4 Faucets
Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
11B-809.9.6 Controls
Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
11B-809.9.6 Controls
Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...