Common Errors in ADA Design
-
4.28.3(3)
(3) The maximum pulse duration shall be two-tenths of one second (0.2 sec) with a maximum duty cycle of 40 percent. The pulse duration is defined as the time interval between initial...
-
A4.28 Alarms
[See subsections ...]
-
Location and Spacing
Location and Spacing Rooms with an area than can be circumscribed by a circle 50 feet in radius can be covered by a single centrally located strobe of 75 cd. For very small rooms,...
-
A4.28.2 Audible Alarms
Audible emergency signals must have an intensity and frequency that can attract the attention of individuals who have partial hearing loss. People over 60 years of age generally have...
-
4.28.3(5)
(5) The flash rate shall be a minimum of 1 Hz and a maximum of 3 Hz.
-
Mounting Height
Mounting Height ADAAG specifies a signal height 80 inches above the highest floor level within the space or 6 inches below the ceiling, whichever is lower. (This can be measured...
-
4.28 Alarms
[See subsections ...]
-
4.28.2* Audible Alarms
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 dbA or exceeds any maximum sound...
-
4.28.2* AUDIBLE ALARMS
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 decibels or exceeds any maximum...
-
4.28 ALARMS
[See subsections ...]
-
A4.28.2 AUDIBLE ALARMS
Audible emergency signals must have an intensity and frequency that can attract the attention of individuals who have partial hearing loss. People over 60 years of age generally have...
-
A4.28 ALARMS
[See subsections ...]
-
§ 37.43(f)(2)(vi)
(vi) When possible, other accessible elements (e.g., parking, storage, alarms).
-
Accessible Boat Slips
Edge protection is not required, but if provided, it can be 4 inches high maximum and 2 inches deep maximum at the continuous clear openings....
-
1003.3.1 Boat Slip Clearance
Edge protection shall be permitted at the continuous clear openings, provided that it is 4 inches (100 mm) high maximum and 2 inches (51 mm) wide maximum. 3....
-
11B-1003.3.1 Boat slip clearance
Edge protection shall be permitted at the continuous clear openings, provided that it is 4 inches (102 mm) high maximum and 2 inches (51 mm) wide maximum. 3....
-
11B-1003.3.1 Boat slip clearance
Edge protection shall be permitted at the continuous clear openings, provided that it is 4 inches (102 mm) high maximum and 2 inches (51 mm) wide maximum....
-
1003.3.2 Boarding Pier Clearances
Edge protection shall be permitted at the continuous clear openings provided that it is 4 inches (100 mm) high maximum and 2 inches (51 mm) wide maximum....
-
11B-1003.3.2 Boarding pier clearances
Edge protection shall be permitted at the continuous clear openings provided that it is 4 inches (102 mm) high maximum and 2 inches (51 mm) wide maximum....
-
11B-1003.3.2 Boarding pier clearances
Edge protection shall be permitted at the continuous clear openings provided that it is 4 inches (102 mm) high maximum and 2 inches (51 mm) wide maximum....
-
11B-215.1 General
Where fire alarm systems and carbon monoxide alarm systems provide audible alarm coverage, alarms shall comply with Section 11B-215....
-
11B-215.1 General
Where fire alarm systems and carbon monoxide alarm systems provide audible alarm coverage, alarms shall comply with Section 11B-215. ...
-
Wiring for Visible Alarms [§215.3]
Wiring for Visible Alarms [§215.3] All employee work areas served by audible fire alarms, regardless of size, must be designed to support later installation of visible alarms after...