Section T504 in the 2016 Non-Rail Vehicle Guidelines establishes specifications for the location of fare collection devices (to ensure that such devices do not impede wheelchair movement...
Search Results "Light Rail"
Commonly Searched Documents
-
T504 Fare Collection Devices
-
810.6.1 Entrances
810.6.1 Entrances. Where signs identify a station or its entrance, at least one sign at each entrance shall comply with 703.2 and shall be placed in uniform locations to the maximum...
-
11B-247.1.2.1 Platform edges
Platform boarding edges shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.1.
-
11B-705.1.2.1 Platform edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform.
-
11B-810.6.1 Entrances
Where signs identify a station or its entrance, at least one sign at each entrance shall comply with Section 11B-703.2 _|Signs; Raised Characters|_ and shall be placed in uniform...
-
705.2 Platform Edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform.
-
810.6.1 Entrances
Where signs identify a station or its entrance, at least one sign at each entrance shall comply with 703.2 and shall be placed in uniform locations to the maximum extent practicable....
-
705.2 Platform Edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform.
-
810.6.1 Entrances
Where signs identify a station or its entrance, at least one sign at each entrance shall comply with 703.2 and shall be placed in uniform locations to the maximum extent practicable....
-
T703 International Symbol of Accessibility
[See subsections ...]
-
T209 Fare Collection Devices
[See subsections ...]
-
T213 Seats
[See subsections ...]
-
705.2 Platform Edges
705.2 Platform Edges. Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform.
-
16. In § 38.111
§ 38.111 [Amended] 16. In § 38.111,
-
10.3.1(12)(a)
(a) If an interior public pay telephone is provided in a transit facility (as defined by the Department of Transportation) at least one interior public text telephone shall be...
-
10.3.1(17)
(17) Where provided, elevators shall be glazed or have transparent panels to allow an unobstructed view both in to and out of the car. Elevators shall comply with 4.10. EXCEPTION:...
-
10.3.3(1)
(1) For the purpose of complying with 4.1.6(2) Alterations to an Area Containing a Primary Function, an area of primary function shall be as defined by applicable provisions of 49...
-
Additional Technical Criteria Considered for Handrails on Ramps
M303.3.3.5 would require handrails to be provided on each side of the ramp when the vertical rise of the ramp exceeds 6 inches. This is consistent with the 2004 ADA and ABA...
-
§ 38.113(d)(1) Requirements
(1) Requirements. Cars which provide level-boarding in stations with high platforms shall be coordinated with the boarding platform or mini-high platform design such that the...
-
§ 38.125(c)(6) Attachment
(6) Attachment—
-
11B-705.1.2.1 Platform edges
11B-705.1.2.1 Platform edges. Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the...
-
§ 38.105 Priority seating signs
[See subsections ...]
-
11B-247.1.2.1 Platform edges
Platform boarding edges shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.1.
-
§ 38.117 Floors, steps and thresholds