New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....
Search Results "Historic Vehicle"
-
§ 38.93(d)(2) Exception
-
§ 38.83(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
-
RV Parking Spaces Within Camping Units With Mobility Features and RV Pull-Up Spaces at Dump Stations [F244.2.3.2.1 and F244.4]
RV parking spaces within camping units with mobility features and RV pull-up spaces at dump stations must comply with the technical requirements for width, surface, and slope of...
-
ADA & Level Boarding – Accessibility Standards Applying to Passenger Rail Cars
49 CFR §§ 27.7(a), 37.5(a), 49 CFR Part 38 December 4, 2012
-
11B-812.8.5 Drive-up
Drive-up EVCS shall not be required to be identified by an ISA.
-
11B-812.10.3 Point-of-sale devices
Where provided, point-of-sale devices shall comply with Sections 11B-707.2, 11B-707.3, 11B-707.7.2, and 11B-707.9.
-
11B-812.10.3 Point-of-sale devices
Where provided, point-of-sale devices shall comply with Sections 11B-707.2, 11B-707.3, 11B-707.7.2, and 11B-707.9.
-
11B-812.8.5 Drive-up
Drive-up EVCS shall not be required to be identified by an ISA.
-
T213 Seats
The 2010 NPRM proposed that non-rail vehicles operating in fixed route systems be required to designate at least two seats as priority seats for passengers with disabilities....
-
10.3.1(9)
(9) In stations covered by this section, rail-to-platform height in new stations shall be coordinated with the floor height of new vehicles so that the vertical difference, measured when...
-
11B-812.8.2 Five to twenty-five
Where five to twenty-five total EVCS are provided, one van accessible EVCS shall be identified by an ISA complying with Section 11B-703.7.2.1. The required standard accessible EVCS...
-
11B-812.8.3 Twenty-six or more
Where twenty-six or more total EVCS are provided, all required van accessible and all required standard accessible EVCS shall be identified by an ISA complying with Section...
-
11B-216.5.3.1 Signs intended for use by pedestrians
Signs intended for use by pedestrians within parking and charging facilities, including directional or informational signs indicating parking sections or levels, shall comply with...
-
11B-216.5.3.1 Signs intended for use by pedestrians
Signs intended for use by pedestrians within parking and charging facilities, including directional or informational signs indicating parking sections or levels, shall comply with...
-
11B-812.8.3 Twenty-six or more
Where twenty-six or more total EVCS are provided, all required van accessible and all required standard accessible EVCS shall be identified by an ISA complying with Section...
-
11B-812.8.2 Five to twenty-five
Where five to twenty-five total EVCS are provided, one van accessible EVCS shall be identified by an ISA complying with Section 11B-703.7.2.1. The required standard accessible EVCS...
-
Section 35.150(b)(2) Safe Harbor (Section-by-Section Analysis)
Historic preservation programs, which are addressed in § 35.150(b)(2) in the current regulation, have been moved to § 35.150(b)(3) in the proposed rule....
-
I fully support ADA requirements and the DGS' efforts. We are reconstructing a 325 space parking lot. 8% will be EVSE ready. 32 EVSE will be installed initially. Including EVSE required ADA spaces, new plan results in 322 spaces. Parking facility no longer complies with minimum parking requirements for facilities. Any suggestions for resolving this conflict for reworking of existing sites subject to CALGreen?
You could consider requesting a variance from full compliance with the parking requirements substantiated by the benefits of electrical vehicle use which relies on installed infrastructure...
-
Alterations and Additions
• When a qualified historic facility is altered, an exception to the alteration requirements of the ADA Standards may be used if the alteration threatens to destroy the historic significance...
-
§ 38.53(a)(2)
or mobility aid users can be accommodated, then such doorway shall have a minimum clear opening of 30 inches to permit wheelchair and mobility aid users to be evacuated to an adjoining vehicle...
-
§ 38.159(b)(9) Platform deflection
The lift platform (not including the entrance ramp) shall not deflect more than 3 degrees (exclusive of vehicle roll or pitch) in any direction between its unloaded position and its position...
-
Utility and Sewage Hookups [1011.2, 1011.3, and 1011.6]
minimum of 30 by 60 inches of clear ground space must be provided with the long side of the space adjoining or overlapping an accessible parking space or pull-up space for recreational vehicles...
-
Section 37.85 Purchase or Lease of New Intercity and Commuter Rail Cars
We would point out that the ADA applies this requirement to all new vehicles....
-
§ 38.159(c)(6) Attachment
When in use for boarding or alighting, the ramp shall be firmly attached to the vehicle so that it is not subject to displacement when loading or unloading a heavy power mobility aid and...