Stations covered by this section shall have identification signs complying with Section 11B-703.5. Signs shall be clearly visible and within the sight lines of standing and sitting...
Search Results "Gender Signage"
-
11B-810.6.3 Station names
-
11B-703.6.3 Text descriptors
Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with Sections 11B-703.2, 11B-703.3 and 11B-703.4.
-
11B-703.2 Raised characters
Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3. Raised characters shall be installed in accordance with...
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character. Heights of low resolution...
-
11B-216.8.3 Signs at toilet and urinal compartments
Where both toilet compartments and urinal compartments are provided, each individual compartment shall be identified with a sign complying with Sections 11B-703.1 through 11B-703.5....
-
11B-703.7.2.3 Volume control telephones
Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 11B-703.7.2.3.
-
11B-703.2.2 Case
Characters shall be uppercase.
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
11B-703.4.2 Location
11B-703.4.2 Location. Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors...
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
F216.9.1 Identification Signs
Public TTYs shall be identified by the International Symbol of TTY complying with 703.7.2.2.
-
216.9.1 Identification Signs
216.9.1 Identification Signs. Public TTYs shall be identified by the International Symbol of TTY complying with 703.7.2.2.
-
11B-216.9.1 Identification signs
Public TTYs shall be identified by the International Symbol of TTY complying with Section 11B-703.7.2.2.
-
At least fifty percent of the entrances must be accessible.
• At least fifty percent of the entrances must be accessible. Those that are not accessible must have signs that direct the public to the nearest accessible entrance.
-
Accessible Entrances
Accessible Entrances One small step at an entrance can make it impossible for individuals using wheelchairs, walkers, canes, or other mobility devices to enter a public facility....
-
1008.1.9.7, Item 5
5. A sign shall be provided on the door located above and within 12 inches (305 mm) of the release device reading: “KEEP PUSHING. THIS DOOR WILL OPEN IN 15 [30] SECONDS ALARM...
-
216.9.1 Identification Signs
Public TTYs shall be identified by the International Symbol of TTY complying with 703.7.2.2.
-
§ 38.27 Priority seating signs
[See subsections ...]
-
11B-216.9.1 Identification signs
Public TTYs shall be identified by the International Symbol of TTY complying with Section 11B-703.7.2.2.
-
11B-216.5.2.2 Additional signs
Signs within parking facilities containing parking spaces complying with Section 11B-502 shall comply with Section 11B-502.8.
-
11B-216.9.1 Identification signs
Public TTYs shall be identified by the International Symbol of TTY complying with Section 11B-703.7.2.2.
-
11B-216.5.2.2 Additional signs
Signs within parking facilities containing parking spaces complying with Section 11B-502 shall comply with Section 11B-502.8.
- Access Board: Tactile Sign Clear Floor Space
-
4.1.6(3)(e)(iii)
(iii) When existing toilet or bathing facilities are being altered and are not made accessible, signage complying with 4.30.1, 4.30.2, 4.30.3, 4.30.5, and 4.30.7 shall be provided indicating...